T1 - Vascular response to percutaneous coronary intervention with biodegradable-polymer vs. new-generation durable-polymer drug-eluting stents
T2 - A meta-analysis of optical coherence tomography imaging trials
AU - Cassese, Salvatore
AU - Xhepa, Erion
AU - Ndrepepa, Gjin
AU - Kufner, Sebastian
AU - Colleran, Roisin
AU - Giacoppo, Daniele
AU - Koppara, Tobias
AU - Mankerious, Nader
AU - Byrne, Robert A.
AU - Laugwitz, Karl Ludwig
AU - Schunkert, Heribert
AU - Fusaro, Massimiliano
AU - Kastrati, Adnan
AU - Joner, Michael
N1 - Publisher Copyright:
© The Author(s) 2018.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Aims Whether biodegradable-polymer drug-eluting stents (BP-DES) induce a vascular response at follow-up more favourable than that of new-generation durable-polymer drug-eluting stents (DP-DES) remains controversial. We sought to evaluate the vascular response to percutaneous coronary intervention (PCI) with BP-DES vs. new-generation DP-DES as assessed by optical coherence tomography (OCT) imaging at follow-up. Methods and results We undertook a meta-analysis of aggregate data by searching electronic scientific databases for investigations of PCI-patients receiving BP-DES vs. new-generation DP-DES and OCT imaging at follow-up. The primary outcome was neointima hyperplasia (NIH) thickness. The co-primary outcome was the incidence of lesions with uncovered struts. The main secondary outcome was the incidence of lesions with malapposed struts. Among 10 trials, a total of 544 PCI-patients were assigned to BP-DES (n = 282) or new-generation DP-DES (n = 262). Of these, 447 participants with 480 treated lesions had analysable OCT imaging at a weighted median follow-up of 7 months. Lesions treated with BP-DES vs. new-generation DP-DES showed comparable NIH thickness [weighted mean difference 95% confidence intervals (CI)= 11.37 (29.25, 6.52); P = 0.21]. However, thick-struts (>100 μm) BP-DES showed less NIH thickness as compared to new-generation DP-DES [20.39 (33.83, 6.95); P = 0.003]. BP-DES vs. new-generation DP-DES showed a higher risk for uncovered struts [odds ratio 95% CI = 3.50 (1.69-7.26); P = 0.0008] and a trend towards higher risk for malapposed struts [2.01 (0.98-4.12); P = 0.06]. Conclusion In PCI-patients with available OCT imaging at follow-up, BP-DES with thicker backbones delay vascular response as compared with new-generation DP-DES. All rights reserved.
AB - Aims Whether biodegradable-polymer drug-eluting stents (BP-DES) induce a vascular response at follow-up more favourable than that of new-generation durable-polymer drug-eluting stents (DP-DES) remains controversial. We sought to evaluate the vascular response to percutaneous coronary intervention (PCI) with BP-DES vs. new-generation DP-DES as assessed by optical coherence tomography (OCT) imaging at follow-up. Methods and results We undertook a meta-analysis of aggregate data by searching electronic scientific databases for investigations of PCI-patients receiving BP-DES vs. new-generation DP-DES and OCT imaging at follow-up. The primary outcome was neointima hyperplasia (NIH) thickness. The co-primary outcome was the incidence of lesions with uncovered struts. The main secondary outcome was the incidence of lesions with malapposed struts. Among 10 trials, a total of 544 PCI-patients were assigned to BP-DES (n = 282) or new-generation DP-DES (n = 262). Of these, 447 participants with 480 treated lesions had analysable OCT imaging at a weighted median follow-up of 7 months. Lesions treated with BP-DES vs. new-generation DP-DES showed comparable NIH thickness [weighted mean difference 95% confidence intervals (CI)= 11.37 (29.25, 6.52); P = 0.21]. However, thick-struts (>100 μm) BP-DES showed less NIH thickness as compared to new-generation DP-DES [20.39 (33.83, 6.95); P = 0.003]. BP-DES vs. new-generation DP-DES showed a higher risk for uncovered struts [odds ratio 95% CI = 3.50 (1.69-7.26); P = 0.0008] and a trend towards higher risk for malapposed struts [2.01 (0.98-4.12); P = 0.06]. Conclusion In PCI-patients with available OCT imaging at follow-up, BP-DES with thicker backbones delay vascular response as compared with new-generation DP-DES. All rights reserved.
KW - biodegradable polymer
KW - drug-eluting stent
KW - durable polymer
KW - meta-analysis
KW - optical coherence tomography
KW - percutaneous coronary intervention
UR - http://www.scopus.com/inward/record.url?scp=85042116309&partnerID=8YFLogxK
U2 - 10.1093/ehjci/jex334
DO - 10.1093/ehjci/jex334
M3 - Article
C2 - 29300853
AN - SCOPUS:85042116309
SN - 2047-2404
VL - 19
SP - 1294
EP - 1301
JO - European Heart Journal Cardiovascular Imaging
JF - European Heart Journal Cardiovascular Imaging
IS - 11
ER -