Skip to main navigation Skip to search Skip to main content

Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device

  • German Heart Institute Berlin

Research output: Contribution to journalArticlepeer-review

32 Scopus citations

Abstract

Rapid advances in paediatric interventional cardiology allow transcatheter closure of patent ductus arteriosus (PDA) in increasingly smaller patients. We describe a successful transcatheter closure of a large tubular PDA in a symptomatic preterm infant of 2,210 g using an Amplatzer Vascular Plug IV device.

Original languageEnglish
Pages (from-to)108-111
Number of pages4
JournalCatheterization and Cardiovascular Interventions
Volume77
Issue number1
DOIs
StatePublished - 1 Jan 2011
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • cardiac catheterization
  • congenital heart disease
  • device closure
  • prematurity
  • transcatheter occlusion

Fingerprint

Dive into the research topics of 'Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device'. Together they form a unique fingerprint.

Cite this