Three-dimensional valve repair - The better care? Midterm results of a saddle-shaped, rigid annuloplasty ring in patients with ischemic mitral regurgitation

Ralf Guenzinger, Eike Philipp Schneider, Thomas Guenther, Petra Wolf, Domenico Mazzitelli, Ruediger Lange, Bernhard Voss

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Objectives Undersized ring annuloplasty is the treatment of choice for functional mitral regurgitation. However, recurrence of mitral regurgitation within the first years is frequent. The aim of this study was to analyze the functional and clinical outcome after mitral valve repair with the 3-dimensional saddle-shaped Edwards GeoForm (Edwards Lifesciences LLC, Irvine, Calif) annuloplasty ring in patients with ischemic mitral regurgitation. Methods Between November 2006 and November 2012, 70 patients (mean age, 68 ± 10 years; mean left ventricular ejection fraction, 40% ± 15%) with functional mitral regurgitation due to ischemic cardiomyopathy underwent mitral valve repair with the Edwards GeoForm annuloplasty ring. Concomitant procedures, such as coronary artery bypass grafting (75.7%), tricuspid valve repair (25.7%), aortic valve replacement (8.6%), and the Maze procedure (4.3%), were performed in 92.9% of patients. Follow-up is 97% complete (mean, 3.0 ± 1.7 years). Transthoracic echocardiography was obtained 2.4 ± 1.7 years postoperatively. Results Thirty-day mortality was 5.9%. Overall survival at 5 years was 71.3% ± 6.9%. At 4 years, overall freedom from recurrence of mitral regurgitation grade 3+ or greater was 92.5% ± 3.6%, and freedom from recurrence of mitral regurgitation grade 2+ or greater was 71.0% ± 8.7%. Three patients required a mitral valve-related reoperation for ring dehiscence. New York Heart Association functional class improved from 3.6 ± 0.6 to 1.6 ± 0.6 during follow-up (P <.05). Mean mitral valve pressure gradient was 3.3 ± 1.8 mm Hg across all ring sizes at the time of follow-up. Conclusions Mitral valve repair with the 3-dimensional saddle-shaped Edwards GeoForm annuloplasty ring in case of ischemic mitral regurgitation shows a low rate of recurrent regurgitation at 4 years. Clinically relevant mitral stenosis was not detected. The importance of secure anchoring of the device in the mitral annulus has to be emphasized to prevent ring dehiscence.

Original languageEnglish
Pages (from-to)176-182
Number of pages7
JournalJournal of Thoracic and Cardiovascular Surgery
Volume148
Issue number1
DOIs
StatePublished - Jul 2014

Fingerprint

Dive into the research topics of 'Three-dimensional valve repair - The better care? Midterm results of a saddle-shaped, rigid annuloplasty ring in patients with ischemic mitral regurgitation'. Together they form a unique fingerprint.

Cite this