TY - JOUR
T1 - The REMEDEE-OCT Study
T2 - An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody–Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis
AU - Jaguszewski, Milosz
AU - Aloysius, Romila
AU - Wang, Wei
AU - Bezerra, Hiram G.
AU - Hill, Jonathan
AU - De Winter, Robbert J.
AU - Karjalainen, Pasi P.
AU - Verheye, Stefan
AU - Wijns, William
AU - Lüscher, Thomas F.
AU - Joner, Michael
AU - Costa, Marco
AU - Landmesser, Ulf
N1 - Publisher Copyright:
© 2017 American College of Cardiology Foundation
PY - 2017/3/13
Y1 - 2017/3/13
N2 - Objectives The aim of the present study was to evaluate vascular healing of the bioengineered COMBO Dual Therapy Stent compared with a cobalt-chromium (CoCr) everolimus-eluting stent (EES) as assessed by optical coherence tomography in patients with acute coronary syndromes. Background CD34+ cells promote endothelial repair after vascular injury. The bioengineered COMBO Dual Therapy Stent combines CD34+ cell–capturing technology with abluminal sirolimus release, but more data from clinical studies evaluating the vascular response are needed. Methods In a prospective randomized multicenter clinical trial, 60 patients with acute coronary syndromes were randomized 1:1 to COMBO or CoCr EES implantation. The primary endpoint was the percentage of uncovered stent struts per stent. Stent assessment by optical coherence tomography was performed at baseline and at 60 days, followed by independent core laboratory analysis. Results The percentage of uncovered struts per stent was higher with the COMBO than the CoCr EES at 60 days (median 14.7% vs. 7.7%; p = 0.04). However, no significant difference in uncovered stent struts was observed in the strut level–based analysis at 60 days, which also accounted for clustering (COMBO vs. CoCr EES; 13.6% vs. 6.9%; p = 0.09; generalized linear mixed models–adjusted analysis). Neointimal thickness at 60 days was lower with the COMBO compared with the CoCr EES (median 30.17 vs. 50.26 μm; p = 0.02; stent-level analysis). There were no significant differences in the frequency of major adverse cardiac events and each component of major adverse cardiac events within the study population between the 2 groups at 30, 60, 180, 360, and 540 days post-procedure. No target vessel stent thrombosis has been documented within 540 days. Conclusions The present multicenter, prospective clinical study for the first time compared the vascular response of the bioengineered COMBO Dual Therapy Stent with a CoCr EES in patients early after acute coronary syndrome by using intracoronary optical coherence tomographic analysis. The percentage of uncovered stent struts per stent was somewhat higher after COMBO versus CoCr EES implantation as detected by optical coherence tomography, associated with reduced neointimal thickness.
AB - Objectives The aim of the present study was to evaluate vascular healing of the bioengineered COMBO Dual Therapy Stent compared with a cobalt-chromium (CoCr) everolimus-eluting stent (EES) as assessed by optical coherence tomography in patients with acute coronary syndromes. Background CD34+ cells promote endothelial repair after vascular injury. The bioengineered COMBO Dual Therapy Stent combines CD34+ cell–capturing technology with abluminal sirolimus release, but more data from clinical studies evaluating the vascular response are needed. Methods In a prospective randomized multicenter clinical trial, 60 patients with acute coronary syndromes were randomized 1:1 to COMBO or CoCr EES implantation. The primary endpoint was the percentage of uncovered stent struts per stent. Stent assessment by optical coherence tomography was performed at baseline and at 60 days, followed by independent core laboratory analysis. Results The percentage of uncovered struts per stent was higher with the COMBO than the CoCr EES at 60 days (median 14.7% vs. 7.7%; p = 0.04). However, no significant difference in uncovered stent struts was observed in the strut level–based analysis at 60 days, which also accounted for clustering (COMBO vs. CoCr EES; 13.6% vs. 6.9%; p = 0.09; generalized linear mixed models–adjusted analysis). Neointimal thickness at 60 days was lower with the COMBO compared with the CoCr EES (median 30.17 vs. 50.26 μm; p = 0.02; stent-level analysis). There were no significant differences in the frequency of major adverse cardiac events and each component of major adverse cardiac events within the study population between the 2 groups at 30, 60, 180, 360, and 540 days post-procedure. No target vessel stent thrombosis has been documented within 540 days. Conclusions The present multicenter, prospective clinical study for the first time compared the vascular response of the bioengineered COMBO Dual Therapy Stent with a CoCr EES in patients early after acute coronary syndrome by using intracoronary optical coherence tomographic analysis. The percentage of uncovered stent struts per stent was somewhat higher after COMBO versus CoCr EES implantation as detected by optical coherence tomography, associated with reduced neointimal thickness.
KW - COMBO stent
KW - OCT
KW - early vascular healing response
KW - neointimal hyperplasia
UR - http://www.scopus.com/inward/record.url?scp=85014563102&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2016.11.040
DO - 10.1016/j.jcin.2016.11.040
M3 - Article
C2 - 28279316
AN - SCOPUS:85014563102
SN - 1936-8798
VL - 10
SP - 489
EP - 499
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 5
ER -