Skip to main navigation Skip to search Skip to main content

The new polarizer devices at RESEDA

  • Technical University of Munich
  • Paul Scherrer Institut

Research output: Contribution to journalConference articlepeer-review

2 Scopus citations

Abstract

In the neutron resonance spin echo method the information about sample dynamics is encoded in the neutron beam polarization measured in the analyzer-detector unit. Thus, the method is not applicable for sample systems and environments, which depolarize the neutron beam strongly. To over come this draw back a neutron analyzer directly before the sample position may be installed to perform MIEZE-I experiments. We compared the performance of a transmission polarizer and a solid-state bender at this position for the neutron resonance spin echo spectrometer RESEDA by Monte Carlo simulations. It turned out, that the polarization as well as the intensity transmitted to the sample position is more advantageous for the transmission polarizer as for the bender. In addition, we present measurements of the polarization and intensity performance of the transmission polarizer already installed at RESEDA to polarize the neutron beam coming from the reactor FRM II. The measurements are in good agreement with Monte Carlo simulations.

Original languageEnglish
Article number012036
JournalJournal of Physics: Conference Series
Volume340
DOIs
StatePublished - 2012
Event5th European Conference on Neutron Scattering, ECNS 2011 - Prague, Czech Republic
Duration: 17 Jul 201121 Jul 2011

Fingerprint

Dive into the research topics of 'The new polarizer devices at RESEDA'. Together they form a unique fingerprint.