Abstract
Measurements of correlation coefficients in neutron beta decay probe the structure of the weak interaction and serve to search for new physics beyond the standard model of particle physics. In this article we describe how pulsed cold neutron beams can be employed to effectively eliminate or control leading sources of systematic uncertainty. As two examples we introduce the existing instrument PERKEO III and the new instrument PERC.
| Original language | English |
|---|---|
| Pages (from-to) | 41-45 |
| Number of pages | 5 |
| Journal | Physics Procedia |
| Volume | 51 |
| DOIs | |
| State | Published - 2014 |
| Externally published | Yes |
| Event | ESS Science Symposium on Neutron Particle Physics at Long Pulse Spallation Sources, NPPatLPS 2013 - Grenoble, France Duration: 25 Mar 2013 → 27 Mar 2013 |
Keywords
- Cold neutrons
- European Spallation Source
- Neutron beta decay
- Proton Electron Radiation Channel
Fingerprint
Dive into the research topics of 'Systematic advantages of pulsed beams for measurements of correlation coefficients in neutron decay'. Together they form a unique fingerprint.Cite this