Abstract
We develop a novel method for structure determination of confined fluids using diffraction-grating-based x-ray interferometry. Within this approach, diffraction from a microfluidic array, which acts both as confinement and transmission diffraction grating, provides the reference wave, whereas the density modulations of the confined fluid, acting as a weak phase object, generate the object wave. The ensemble-averaged density profile of the fluid perpendicular to the confining channel is then unambiguously obtained from the interference between the reference and object waves by direct Fourier inversion.
Original language | English |
---|---|
Pages (from-to) | 20522-20529 |
Number of pages | 8 |
Journal | Optics Express |
Volume | 16 |
Issue number | 25 |
DOIs | |
State | Published - 8 Dec 2008 |
Externally published | Yes |