TY - GEN
T1 - Sieve-valve-aware synthesis of flow-based microfluidic biochips considering specific biological execution limitations
AU - Li, Mengchu
AU - Tseng, Tsun Ming
AU - Li, Bing
AU - Ho, Tsung Yi
AU - Schlichtmann, Ulf
N1 - Publisher Copyright:
© 2016 EDAA.
PY - 2016/4/25
Y1 - 2016/4/25
N2 - Microfluidic biochips are being used to perform ever more complex and error-prone bioassays. This results in increasing demand for design automation for such biochips, as these sophisticated designs are beyond the scope of manual design. So far, much research in the field of design automation has been devoted to satisfy this demand from biology, but the gap between design automation and biology is still huge. To narrow this gap, we propose a synthesis method in which sieve valves, which are key components in flow-based microfluidic biochips, are considered for the first time. In addition, we integrate three more constraints into our synthesis that are commonly seen in bioassays but have so far been neglected by design automation: immediate execution, mutual exclusion, and parallel execution. Experiments show that compared with traditional synthesis, this new method shows significant improvements, and the gap between design automation and biology is getting bridged.
AB - Microfluidic biochips are being used to perform ever more complex and error-prone bioassays. This results in increasing demand for design automation for such biochips, as these sophisticated designs are beyond the scope of manual design. So far, much research in the field of design automation has been devoted to satisfy this demand from biology, but the gap between design automation and biology is still huge. To narrow this gap, we propose a synthesis method in which sieve valves, which are key components in flow-based microfluidic biochips, are considered for the first time. In addition, we integrate three more constraints into our synthesis that are commonly seen in bioassays but have so far been neglected by design automation: immediate execution, mutual exclusion, and parallel execution. Experiments show that compared with traditional synthesis, this new method shows significant improvements, and the gap between design automation and biology is getting bridged.
UR - https://www.scopus.com/pages/publications/84973640337
M3 - Conference contribution
AN - SCOPUS:84973640337
T3 - Proceedings of the 2016 Design, Automation and Test in Europe Conference and Exhibition, DATE 2016
SP - 624
EP - 629
BT - Proceedings of the 2016 Design, Automation and Test in Europe Conference and Exhibition, DATE 2016
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 19th Design, Automation and Test in Europe Conference and Exhibition, DATE 2016
Y2 - 14 March 2016 through 18 March 2016
ER -