Abstract
An experimental procedure was developed to detect partial side track erasure. The procedure was applied to examine four different head designs from four different vendors (A: stitched-pole, nonrecessed; B-D: nonstitched-pole). Time-resolved scanning MOKE measurements were made and SEM micrographs of the heads were taken.
Original language | English |
---|---|
Pages (from-to) | HP-01 |
Journal | Digests of the Intermag Conference |
State | Published - 2000 |
Externally published | Yes |
Event | 2000 IEEE International Magnetics Conference-2000 IEEE INTERMAG - Toronto, Ont, Can Duration: 9 Apr 2000 → 13 Apr 2000 |