TY - JOUR
T1 - Serial echocardiographic evaluation of the Perimount Magna Ease prosthesis
AU - Mayr, Benedikt
AU - Burri, Melchior
AU - Vitanova, Keti
AU - Prinzing, Anatol
AU - Goppel, Gertrud
AU - Krane, Markus
AU - Lange, Rüdiger
AU - Günzinger, Ralf
N1 - Publisher Copyright:
© 2021 AME Publishing Company. All rights reserved.
PY - 2021/7
Y1 - 2021/7
N2 - Background: The Carpentier-Edwards Perimount Magna Ease prosthesis (PME) represents the latest generation of stented bioprostheses used for surgical aortic valve replacement (SAVR). The aim of our study was to evaluate the long-term clinical outcome and hemodynamic performance of the prosthesis with a focus on the incidence and course of structural valve deterioration (SVD) by serial echocardiographic examinations. Methods: SAVR with the PME was performed in 58 consecutive patients between 2007 and 2008. Transthoracic echocardiography was performed preoperatively, at discharge and annually during a 10-year follow-up at the German Heart Center Munich. Results: Mean age at surgery was 62±14 years. At discharge (n=57), the overall mean pressure gradient (MPG) and effective orifice area (EOA) were 15.8±4.1 mmHg and 1.8±0.4 cm2, respectively. Moderate patient-prosthesis mismatch (PPM) was present in 18 patients (32%) and severe PPM in 6 patients (11%) at discharge. Ten years following SAVR (n=33), the overall MPG was 16.6±7.3 mmHg and EOA was 1.3±0.4 cm2. Thirty-day and late mortality was 2% (n=1) and 21% (n=12), respectively. Survival at 1, 5, and 10 years was 94.7%±3.3%, 91.1%±4.1%, and 77.3%±5.9%, respectively. Freedom from reoperation at 10 years was 88.8%±4.7%. Ten years after PME implantation the cumulative incidence of any SVD, severe SVD, and bioprosthetic valve failure (BVF) was 25%±6%, 14%±5%, and 16%±5%, respectively. Conclusions: The PME shows an excellent hemodynamic performance over the course of 10 years with development of clinically relevant SVD as late as 6 years post implant, and a 10-year incidence of severe SVD of 14%.
AB - Background: The Carpentier-Edwards Perimount Magna Ease prosthesis (PME) represents the latest generation of stented bioprostheses used for surgical aortic valve replacement (SAVR). The aim of our study was to evaluate the long-term clinical outcome and hemodynamic performance of the prosthesis with a focus on the incidence and course of structural valve deterioration (SVD) by serial echocardiographic examinations. Methods: SAVR with the PME was performed in 58 consecutive patients between 2007 and 2008. Transthoracic echocardiography was performed preoperatively, at discharge and annually during a 10-year follow-up at the German Heart Center Munich. Results: Mean age at surgery was 62±14 years. At discharge (n=57), the overall mean pressure gradient (MPG) and effective orifice area (EOA) were 15.8±4.1 mmHg and 1.8±0.4 cm2, respectively. Moderate patient-prosthesis mismatch (PPM) was present in 18 patients (32%) and severe PPM in 6 patients (11%) at discharge. Ten years following SAVR (n=33), the overall MPG was 16.6±7.3 mmHg and EOA was 1.3±0.4 cm2. Thirty-day and late mortality was 2% (n=1) and 21% (n=12), respectively. Survival at 1, 5, and 10 years was 94.7%±3.3%, 91.1%±4.1%, and 77.3%±5.9%, respectively. Freedom from reoperation at 10 years was 88.8%±4.7%. Ten years after PME implantation the cumulative incidence of any SVD, severe SVD, and bioprosthetic valve failure (BVF) was 25%±6%, 14%±5%, and 16%±5%, respectively. Conclusions: The PME shows an excellent hemodynamic performance over the course of 10 years with development of clinically relevant SVD as late as 6 years post implant, and a 10-year incidence of severe SVD of 14%.
KW - Aortic valve replacement
KW - Aortic valve stenosis
KW - Structural valve deterioration (SVD)
UR - http://www.scopus.com/inward/record.url?scp=85111560590&partnerID=8YFLogxK
U2 - 10.21037/jtd-21-481
DO - 10.21037/jtd-21-481
M3 - Article
AN - SCOPUS:85111560590
SN - 2072-1439
VL - 13
SP - 4104
EP - 4113
JO - Journal of Thoracic Disease
JF - Journal of Thoracic Disease
IS - 7
ER -