TY - JOUR
T1 - Separating Movement and Gravity Components in an Acceleration Signal and Implications for the Assessment of Human Daily Physical Activity
AU - van Hees, Vincent T.
AU - Gorzelniak, Lukas
AU - Dean León, Emmanuel Carlos
AU - Eder, Martin
AU - Pias, Marcelo
AU - Taherian, Salman
AU - Ekelund, Ulf
AU - Renström, Frida
AU - Franks, Paul W.
AU - Horsch, Alexander
AU - Brage, Søren
N1 - Funding Information:
Vincent van Hees, who led on this manuscript, was funded by a BBSRC industry-CASE studentship. This studentship came with funding from both the BBSRC and an industry partner, Unilever Discover Ltd in this case ( http://www.bbsrc.ac.uk/web/FILES/Guidelines/studentship_handbook.pdf ). Unilever Discover Ltd had no involvement in the study as presented and was only informed about progress and final results. This does not alter the authors' adherence to all the PLOS ONE policies on sharing data and materials.
PY - 2013/4/23
Y1 - 2013/4/23
N2 - Introduction:Human body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment.Methods:An industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22-65 yr), and wrist in 63 women (20-35 yr) in whom daily activity-related energy expenditure (PAEE) was available.Results:In the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN).Conclusion:In conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity.
AB - Introduction:Human body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment.Methods:An industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22-65 yr), and wrist in 63 women (20-35 yr) in whom daily activity-related energy expenditure (PAEE) was available.Results:In the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN).Conclusion:In conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity.
UR - http://www.scopus.com/inward/record.url?scp=84876514686&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0061691
DO - 10.1371/journal.pone.0061691
M3 - Article
C2 - 23626718
AN - SCOPUS:84876514686
SN - 1932-6203
VL - 8
JO - PLoS ONE
JF - PLoS ONE
IS - 4
M1 - e61691
ER -