T1 - Self-gated radial MRI for respiratory motion compensation on hybrid PET/MR systems
AU - Grimm, Robert
AU - Fürst, Sebastian
AU - Dregely, Isabel
AU - Forman, Christoph
AU - Hutter, Jana Maria
AU - Ziegler, Sibylle I.
AU - Nekolla, Stephan
AU - Kiefer, Berthold
AU - Schwaiger, Markus
AU - Hornegger, Joachim
AU - Block, Tobias
PY - 2013
Y1 - 2013
N2 - Accurate localization and uptake quantification of lesions in the chest and abdomen using PET imaging is challenging due to the respiratory motion during the exam. The advent of hybrid PET/MR systems offers new ways to compensate for respiratory motion without exposing the patient to additional radiation. The use of self-gated reconstructions of a 3D radial stack-of-stars GRE acquisition is proposed to derive a high-resolution MRI motion model. The self-gating signal is used to perform respiratory binning of the simultaneously acquired PET raw data. Matching μ-maps are generated for every bin, and post-reconstruction registration is performed in order to obtain a motion-compensated PET volume from the individual gates. The proposed method is demonstrated in-vivo for three clinical patients. Motion-corrected reconstructions are compared against ungated and gated PET reconstructions. In all cases, motion-induced blurring of lesions in the liver and lung was substantially reduced, without compromising SNR as it is the case for gated reconstructions.
AB - Accurate localization and uptake quantification of lesions in the chest and abdomen using PET imaging is challenging due to the respiratory motion during the exam. The advent of hybrid PET/MR systems offers new ways to compensate for respiratory motion without exposing the patient to additional radiation. The use of self-gated reconstructions of a 3D radial stack-of-stars GRE acquisition is proposed to derive a high-resolution MRI motion model. The self-gating signal is used to perform respiratory binning of the simultaneously acquired PET raw data. Matching μ-maps are generated for every bin, and post-reconstruction registration is performed in order to obtain a motion-compensated PET volume from the individual gates. The proposed method is demonstrated in-vivo for three clinical patients. Motion-corrected reconstructions are compared against ungated and gated PET reconstructions. In all cases, motion-induced blurring of lesions in the liver and lung was substantially reduced, without compromising SNR as it is the case for gated reconstructions.
UR - http://www.scopus.com/inward/record.url?scp=84885937092&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-40760-4_3
DO - 10.1007/978-3-642-40760-4_3
M3 - Conference contribution
C2 - 24505739
AN - SCOPUS:84885937092
SN - 9783642407598
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 17
EP - 24
BT - Medical Image Computing and Computer-Assisted Intervention, MICCAI 2013 - 16th International Conference, Proceedings
T2 - 16th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2013
Y2 - 22 September 2013 through 26 September 2013