Abstract
Basis for the application of quantitative acoustic emission techniques is the 3D-localization of the events with the highest precision. A procedure have to be found to analyze a large number of events and to extract the onset times of the signals automatically - the different travel times between source and sensors can be used to calculate the source locations. An algorithm is presented which meets the requirements.
| Translated title of the contribution | Development of a procedure for automated localization of acoustic emission sources |
|---|---|
| Original language | German |
| Pages (from-to) | 342-347 |
| Number of pages | 6 |
| Journal | Materialpruefung/Materials Testing |
| Volume | 41 |
| Issue number | 9 |
| State | Published - 1999 |
Fingerprint
Dive into the research topics of 'Development of a procedure for automated localization of acoustic emission sources'. Together they form a unique fingerprint.Cite this