T1 - Robust Multi-Target Sample Preparation on MEDA Biochips Obviating Waste Production
AU - Poddar, Sudip
AU - Banerjee, Tapalina
AU - Wille, Robert
AU - Bhattacharya, Bhargab B.
N1 - Publisher Copyright:
© 2020 ACM.
PY - 2021/1
Y1 - 2021/1
N2 - Digital microfluidic biochips have fueled a paradigm shift in implementing bench-top laboratory experiments on a single tiny chip, thus replacing costly and bulky equipment. However, because of imprecise fluidic functions, several volumetric split errors may occur during the execution of bioassays. Earlier approaches to error-correcting sample preparation addressed this problem by using a cyberphysical system yielding several drawbacks such as increased sample preparation cost and time, and uncertainty in assay completion time. In addition, error correction for only a single-target sample has been considered so far, although many assays require the production of multi-target samples. In this work, we present an error-free dilution technique that guarantees the correctness of the resulting concentration factor of a sample without performing any additional roll-back or roll-forward action. To the best of our knowledge, we are the first to present a solution strategy for tackling dispensing errors during sample preparation. We use micro-electrode-dot-array biochips that offer the advantages of manipulating fractional volumes of droplets (aliquots) for navigation, as well as mix-split operations. Instead of performing traditional mix-and-split steps with integral-volume droplets, we execute only an aliquoting-and-mix sequence using differential-size aliquots. Thus, all split operations, which are the main source of errors in conventional digital microfluidic biochips, are completely eliminated, and hence neither sensing nor any correcting action is needed, and further, no management of intermediate waste droplets is needed. Additionally, the procedure can be fully parallelized for accurately producing multiple dilutions of a sample. Experimental results corroborate the superiority of the proposed method in terms of error management, as well as sample preparation cost and time.
AB - Digital microfluidic biochips have fueled a paradigm shift in implementing bench-top laboratory experiments on a single tiny chip, thus replacing costly and bulky equipment. However, because of imprecise fluidic functions, several volumetric split errors may occur during the execution of bioassays. Earlier approaches to error-correcting sample preparation addressed this problem by using a cyberphysical system yielding several drawbacks such as increased sample preparation cost and time, and uncertainty in assay completion time. In addition, error correction for only a single-target sample has been considered so far, although many assays require the production of multi-target samples. In this work, we present an error-free dilution technique that guarantees the correctness of the resulting concentration factor of a sample without performing any additional roll-back or roll-forward action. To the best of our knowledge, we are the first to present a solution strategy for tackling dispensing errors during sample preparation. We use micro-electrode-dot-array biochips that offer the advantages of manipulating fractional volumes of droplets (aliquots) for navigation, as well as mix-split operations. Instead of performing traditional mix-and-split steps with integral-volume droplets, we execute only an aliquoting-and-mix sequence using differential-size aliquots. Thus, all split operations, which are the main source of errors in conventional digital microfluidic biochips, are completely eliminated, and hence neither sensing nor any correcting action is needed, and further, no management of intermediate waste droplets is needed. Additionally, the procedure can be fully parallelized for accurately producing multiple dilutions of a sample. Experimental results corroborate the superiority of the proposed method in terms of error management, as well as sample preparation cost and time.
KW - Microfluidic biochip
KW - bioassay
KW - cyberphysical system
KW - error-correcting
KW - robust
KW - roll-back and roll-forward error-recovery
KW - sample preparation
UR - http://www.scopus.com/inward/record.url?scp=85099101447&partnerID=8YFLogxK
U2 - 10.1145/3414061
DO - 10.1145/3414061
M3 - Article
AN - SCOPUS:85099101447
SN - 1084-4309
VL - 26
JO - ACM Transactions on Design Automation of Electronic Systems
JF - ACM Transactions on Design Automation of Electronic Systems
IS - 1
M1 - 7
ER -