TY - GEN
T1 - Robot-assisted assessment of wrist proprioception
T2 - 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
AU - Contu, Sara
AU - Marini, Francesca
AU - Cappello, Leonardo
AU - Masia, Lorenzo
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/10/13
Y1 - 2016/10/13
N2 - Proprioception is essential for planning and controlling limb posture and movement. In our recent work, we introduced a standardized robot-aided method for measuring proprioceptive discrimination thresholds at the wrist to obtain reliable and accurate measures of proprioceptive acuity. Weber's law defines discrimination thresholds as a constant ratio between the just noticeable difference and the reference or standard stimulus. Reporting Weber's fractions thus provides the possibility of comparing results with the reports of others collected worldwide. This work aims to determine that Weber's Law holds for proprioceptive discrimination thresholds and to provide Weber's fraction for wrist joint proprioception. To this end, eight healthy subjects experienced two passive wrist movements of different amplitude and verbally indicated which was larger. An adaptive psychophysical procedure established the amplitude of the largest stimulus according to participants' responses. This comparison stimulus was then compared to a standard stimulus amplitude of 10°, 20°, 30° or 40°. The discrimination thresholds for each standard stimulus were established at the 75% correct response level. The obtained thresholds followed Weber's Law indicating that larger amplitudes were associated with higher discrimination thresholds. Based on a linear regression function the overall Weber's fraction, defined as the slope of the line, was computed to be 0.09. This result expands the present limited knowledge on wrist proprioception showing that its proprioceptive acuity follows Weber's law.
AB - Proprioception is essential for planning and controlling limb posture and movement. In our recent work, we introduced a standardized robot-aided method for measuring proprioceptive discrimination thresholds at the wrist to obtain reliable and accurate measures of proprioceptive acuity. Weber's law defines discrimination thresholds as a constant ratio between the just noticeable difference and the reference or standard stimulus. Reporting Weber's fractions thus provides the possibility of comparing results with the reports of others collected worldwide. This work aims to determine that Weber's Law holds for proprioceptive discrimination thresholds and to provide Weber's fraction for wrist joint proprioception. To this end, eight healthy subjects experienced two passive wrist movements of different amplitude and verbally indicated which was larger. An adaptive psychophysical procedure established the amplitude of the largest stimulus according to participants' responses. This comparison stimulus was then compared to a standard stimulus amplitude of 10°, 20°, 30° or 40°. The discrimination thresholds for each standard stimulus were established at the 75% correct response level. The obtained thresholds followed Weber's Law indicating that larger amplitudes were associated with higher discrimination thresholds. Based on a linear regression function the overall Weber's fraction, defined as the slope of the line, was computed to be 0.09. This result expands the present limited knowledge on wrist proprioception showing that its proprioceptive acuity follows Weber's law.
UR - http://www.scopus.com/inward/record.url?scp=85009106018&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2016.7591754
DO - 10.1109/EMBC.2016.7591754
M3 - Conference contribution
C2 - 28269302
AN - SCOPUS:85009106018
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 4610
EP - 4613
BT - 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 16 August 2016 through 20 August 2016
ER -