RINGVERSUCH ZUR MESSUNG POLYCHLORIERTER DIBENZODIOXINE UND -FURANE AN ARBEITSPLATZEN

Translated title of the contribution: Round robin test for measuring polychlorinated dibenzodioxins and -furans in workplace air
  • N. Lichtenstein
  • , R. Stockmann
  • , B. Bogdoll
  • , J. Hosseinpour
  • , K. Jaeger
  • , H. Kieper
  • , H. Linde
  • , K. Schramm

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Six simultaneous samplings were carried out in an aluminium recycling plant to validate a method for determining the concentration of polychlorinated dibenzodioxines and -furans (PCDD/PCDF) in workplace air. The sampling device was developed in the 'Berufsgenossenschaftliches Institut fur Arbeitssicherheit' (BIA) and is able to sample particulate PCDD/PCDF using a glass fiber filter according to the total dust definition and filter-passing PCDD/PCDF using a layer of polyprethane foam. The samples were analysed in six different laboratories, which were allowed to use different analytical methods. The relative standard deviation for the results is 25%. This satisfies the requirements of DIN EN 482 for the performance of procedures for measuring chemical agents.

Translated title of the contributionRound robin test for measuring polychlorinated dibenzodioxins and -furans in workplace air
Original languageGerman
Pages (from-to)239-245
Number of pages7
JournalGefahrstoffe Reinhaltung der Luft
Volume56
Issue number6
StatePublished - 1996
Externally publishedYes

Fingerprint

Dive into the research topics of 'Round robin test for measuring polychlorinated dibenzodioxins and -furans in workplace air'. Together they form a unique fingerprint.

Cite this