TY - JOUR
T1 - Restenosis after coronary placement of various stent types
AU - Kastrati, Adnan
AU - Mehilli, Julinda
AU - Dirschinger, Josef
AU - Pache, Jürgen
AU - Ulm, Kurt
AU - Schühlen, Helmut
AU - Seyfarth, Melchior
AU - Schmitt, Claus
AU - Blasini, Rudolf
AU - Neumann, Franz Josef
AU - Schömig, Albert
PY - 2001/1/1
Y1 - 2001/1/1
N2 - Coronary stent implantation is being performed in an increasing number of patients with a wide spectrum of clinical and lesion characteristics. A variety of stent designs are now available and continuous efforts are being made to improve the stent placement procedure. The objective of this study was to perform a comprehensive analysis of the relation between clinical, lesion, and procedural factors, and restenosis after intracoronary stenting in a large and unselected population of patients. A consecutive series of 4,510 patients with coronary stent placement was analyzed. Exclusion criteria were only a failed procedure and an adverse outcome within the first month after the intervention. Follow-up angiography was performed in 80% of patients at 6 months. Clinical, lesion, and procedural data from all 3,370 patients (4,229 stented lesions) with follow-up angiography were analyzed in a logistic regression model for restenosis (≥50% diameter stenosis). Clinical factors contributed to the predictive power of the model much less than lesion and procedural factors. The strongest risk factor for restenosis was a small vessel size, with a 79% increase in the risk for a vessel of 2.7 mm versus a vessel of 3.4 mm in diameter. Stent design was the second strongest factor; the incidence of restenosis ranged from 20.0% to 50.3% depending on the stent type implanted. In conclusion, this study demonstrates the predominant role of lesion and procedural factors in determining the occurrence of restenosis after coronary stent placement. Among these factors, stent design appears to play a particularly important role in the hyperplastic response of the vessel wall.
AB - Coronary stent implantation is being performed in an increasing number of patients with a wide spectrum of clinical and lesion characteristics. A variety of stent designs are now available and continuous efforts are being made to improve the stent placement procedure. The objective of this study was to perform a comprehensive analysis of the relation between clinical, lesion, and procedural factors, and restenosis after intracoronary stenting in a large and unselected population of patients. A consecutive series of 4,510 patients with coronary stent placement was analyzed. Exclusion criteria were only a failed procedure and an adverse outcome within the first month after the intervention. Follow-up angiography was performed in 80% of patients at 6 months. Clinical, lesion, and procedural data from all 3,370 patients (4,229 stented lesions) with follow-up angiography were analyzed in a logistic regression model for restenosis (≥50% diameter stenosis). Clinical factors contributed to the predictive power of the model much less than lesion and procedural factors. The strongest risk factor for restenosis was a small vessel size, with a 79% increase in the risk for a vessel of 2.7 mm versus a vessel of 3.4 mm in diameter. Stent design was the second strongest factor; the incidence of restenosis ranged from 20.0% to 50.3% depending on the stent type implanted. In conclusion, this study demonstrates the predominant role of lesion and procedural factors in determining the occurrence of restenosis after coronary stent placement. Among these factors, stent design appears to play a particularly important role in the hyperplastic response of the vessel wall.
UR - http://www.scopus.com/inward/record.url?scp=0035178080&partnerID=8YFLogxK
U2 - 10.1016/S0002-9149(00)01268-6
DO - 10.1016/S0002-9149(00)01268-6
M3 - Article
C2 - 11137830
AN - SCOPUS:0035178080
SN - 0002-9149
VL - 87
SP - 34
EP - 39
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 1
ER -