Skip to main navigation Skip to search Skip to main content

Resistance index in mediastinal lymph nodes: A feasibility study

  • Felix J.F. Herth
  • , Kazuhiro Yasufuku
  • , Ralf Eberhardt
  • , Hans Hoffmann
  • , Mark Krasnik
  • , Armin Ernst
  • Thoraxklinik at the University Hospital Heidelberg
  • Chiba-U
  • University of Gentofte
  • Harvard Medical School

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

OBJECTIVE: The purpose of this study was to determine the range of Doppler ultrasonographic measurements of the resistance index in presumed normal mediastinal lymph node arteries. METHODS: Consecutive patients referred for bronchoscopy for various indications and normal CT findings in the mediastinum were included. The resistance index (RI) in mediastinal lymph node arteries was examined with Color Doppler ultrasonography. The peak systolic velocity (PSV) and the end-diastolic velocity were measured, which allowed for calculation of the resistance indices in different lymph node stations and in each lymph node artery. RESULTS: Eighty-nine patients (32 female; 57 male; mean age, 42.2 years) were examined, and of these, 50 patients (24 female; 36 male; mean age, 44.7 years) had measurable RIs. PSV and ESV were measured in all visible nodes (n = 196) and an interpretable value was obtained in 127 nodes (2.5 nodes per patient.). The median PSV was 15.6 cm/s (range, 8.9-23.2 cm/s, SD ± 2.6, 25-75% percentile 13.8-17.5), and the median end-diastolic velocity was 5.8 cm/s (range, 3.6-11.4 cm/s, SD 1.15 cm/s, 25-75% percentile 5.1-6.3). The median RI values for arteries were 0.63 (range, 0.52-0.75, SD 0.04, 25-75% percentile 0.6-0.64) respectively. The Doppler measurements lasted on average 4.3 minutes and no complications were seen. CONCLUSION: Color Doppler ultrasonography allows for quantification of velocities like PSV and ESV in mediastinal lymph node arteries, which in turn allow calculation of a resistance index. Knowledge of the resistance index's normal range (which describes the resistance of the blood flow within the lumen of the lymph node artery) may be a useful adjunct to the ultrasonic assessment of the mediastinum.

Original languageEnglish
Pages (from-to)348-350
Number of pages3
JournalJournal of Thoracic Oncology
Volume3
Issue number4
DOIs
StatePublished - Apr 2008
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bronchoscopy
  • Cancer
  • Endobronchial ultrasound
  • Lymph node
  • Resistance index

Fingerprint

Dive into the research topics of 'Resistance index in mediastinal lymph nodes: A feasibility study'. Together they form a unique fingerprint.

Cite this