TY - JOUR
T1 - Repair of Mitral Valves with Severe Annular Dilatation and Abundant Leaflet Tissue Using a Prosthetic Ring with a Large Anterior-Posterior Diameter
AU - Sideris, Konstantinos
AU - Burri, Melchior
AU - Bordne, Joanna
AU - Vitanova, Keti
AU - Voss, Bernhard
AU - Krane, Markus
AU - Lange, Rüdiger
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/3/1
Y1 - 2022/3/1
N2 - Backround: Mitral valve (MV) repair in the case of a large anterior-posterior diameter and redundant valve tissue remains challenging and favors repair with a ring that exhibits a large anterior-posterior diameter. Compared to other available rings, the Medtronic Simulus annuloplasty ring shows the largest anterior-posterior diameter. This study reports for the first time mid-term results using this annuloplasty ring. Methods: Between 11/2015 and 12/2019, a total of 378 patients underwent MV repair for degenerative mitral regurgitation using the Medtronic Simulus ring, according to the following selection criteria: large MV annuli, abundant leaflet tissue (i.e., Barlow disease), and risk for SAM. Results: Overall survival after 5 years was 90.8 ± 4.6%. Five patients required valve-related reoperations because of ring dehiscence (n = 1), progression of native valve disease (n = 2), dehiscence of quadrangular resection suture (n = 1), and endocarditis (n = 1). The cumulative incidence of valve-related reoperation at 5 years was 1.3 ± 0.5%. At latest follow-up, echocardiography demonstrated excellent valve function with no/mild MR in 299 patients (94.6%). Two patients (0.6%) had more than moderate MR. No patient developed SAM after repair. Conclusion: Repair of MV with large annuli and abundant leaflet tissue with the Medtronic Simulus annuloplasty ring shows excellent mid-term results regarding reoperation rates and recurrent MR.
AB - Backround: Mitral valve (MV) repair in the case of a large anterior-posterior diameter and redundant valve tissue remains challenging and favors repair with a ring that exhibits a large anterior-posterior diameter. Compared to other available rings, the Medtronic Simulus annuloplasty ring shows the largest anterior-posterior diameter. This study reports for the first time mid-term results using this annuloplasty ring. Methods: Between 11/2015 and 12/2019, a total of 378 patients underwent MV repair for degenerative mitral regurgitation using the Medtronic Simulus ring, according to the following selection criteria: large MV annuli, abundant leaflet tissue (i.e., Barlow disease), and risk for SAM. Results: Overall survival after 5 years was 90.8 ± 4.6%. Five patients required valve-related reoperations because of ring dehiscence (n = 1), progression of native valve disease (n = 2), dehiscence of quadrangular resection suture (n = 1), and endocarditis (n = 1). The cumulative incidence of valve-related reoperation at 5 years was 1.3 ± 0.5%. At latest follow-up, echocardiography demonstrated excellent valve function with no/mild MR in 299 patients (94.6%). Two patients (0.6%) had more than moderate MR. No patient developed SAM after repair. Conclusion: Repair of MV with large annuli and abundant leaflet tissue with the Medtronic Simulus annuloplasty ring shows excellent mid-term results regarding reoperation rates and recurrent MR.
KW - Mitral systolic anterior motion
KW - Mitral valve repair
KW - Outcomes
UR - http://www.scopus.com/inward/record.url?scp=85126633606&partnerID=8YFLogxK
U2 - 10.3390/jcm11061709
DO - 10.3390/jcm11061709
M3 - Article
AN - SCOPUS:85126633606
SN - 2077-0383
VL - 11
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 6
M1 - 1709
ER -