TY - JOUR
T1 - Rapid assessment of the coenzyme Q10 redox state using ultrahigh performance liquid chromatography tandem mass spectrometry
AU - Tang, Zhi
AU - Li, Shangfu
AU - Guan, Xinyuan
AU - Schmitt-Kopplin, Philippe
AU - Lin, Shuhai
AU - Cai, Zongwei
N1 - Publisher Copyright:
© the Partner Organisations 2014.
PY - 2014
Y1 - 2014
N2 - An improved method for accurate and rapid assessment of the coenzyme Q10 (CoQ10) redox state using ultrahigh performance liquid chromatography tandem mass spectrometry was described, with particular attention given to the instability of the reduced form of CoQ10 during sample preparation, chromatographic separation and mass spectrometric detection. As highly lipophilic compounds in complex biological matrices, both reduced and oxidized forms of CoQ10 were extracted simultaneously from the tissue samples by methanol which is superior to ethanol and isopropanol. After centrifugation, the supernatants were immediately separated on a C18 column with isocratic elution using methanol containing 2 mM ammonium acetate as a non-aqueous mobile phase, and detected by positive electrospray ionization tandem mass spectrometry in multiple reaction monitoring (MRM) mode. Ammonium acetate as an additive in methanol provided enhanced mass spectrometric responses for both forms of CoQ10, primarily due to stable formation of adduct ions [M + NH4]+, which served as precursor ions in positive ionization MRM transitions. The assay showed a linear range of 8.6-8585 ng mL-1 for CoQ10H2 and 8.6-4292 ng mL-1 for CoQ10. The limits of detection (LODs) were 7.0 and 1.0 ng mL-1 and limits of quantification (LOQs) were 15.0 and 5.0 ng mL-1 for CoQ10H2 and CoQ10, respectively. This rapid extractive and analytical method could avoid artificial auto-oxidation of the reduced form of CoQ10, enabling the native redox state assessment. This reliable method was also successfully applied for the measurement of the CoQ10 redox state in liver tissues of mice exposed to 2,3,7,8-tetrachlorodibenzo-p-dioxin, revealing the down-regulated mitochondrial electron transport chain.
AB - An improved method for accurate and rapid assessment of the coenzyme Q10 (CoQ10) redox state using ultrahigh performance liquid chromatography tandem mass spectrometry was described, with particular attention given to the instability of the reduced form of CoQ10 during sample preparation, chromatographic separation and mass spectrometric detection. As highly lipophilic compounds in complex biological matrices, both reduced and oxidized forms of CoQ10 were extracted simultaneously from the tissue samples by methanol which is superior to ethanol and isopropanol. After centrifugation, the supernatants were immediately separated on a C18 column with isocratic elution using methanol containing 2 mM ammonium acetate as a non-aqueous mobile phase, and detected by positive electrospray ionization tandem mass spectrometry in multiple reaction monitoring (MRM) mode. Ammonium acetate as an additive in methanol provided enhanced mass spectrometric responses for both forms of CoQ10, primarily due to stable formation of adduct ions [M + NH4]+, which served as precursor ions in positive ionization MRM transitions. The assay showed a linear range of 8.6-8585 ng mL-1 for CoQ10H2 and 8.6-4292 ng mL-1 for CoQ10. The limits of detection (LODs) were 7.0 and 1.0 ng mL-1 and limits of quantification (LOQs) were 15.0 and 5.0 ng mL-1 for CoQ10H2 and CoQ10, respectively. This rapid extractive and analytical method could avoid artificial auto-oxidation of the reduced form of CoQ10, enabling the native redox state assessment. This reliable method was also successfully applied for the measurement of the CoQ10 redox state in liver tissues of mice exposed to 2,3,7,8-tetrachlorodibenzo-p-dioxin, revealing the down-regulated mitochondrial electron transport chain.
UR - http://www.scopus.com/inward/record.url?scp=84908325876&partnerID=8YFLogxK
U2 - 10.1039/c4an00760c
DO - 10.1039/c4an00760c
M3 - Article
AN - SCOPUS:84908325876
SN - 0003-2654
VL - 139
SP - 5600
EP - 5604
JO - Analyst
JF - Analyst
IS - 21
ER -