Skip to main navigation Skip to search Skip to main content

Quantitative multi-slice computed tomography assessment of the mitral valvular complex for transcatheter mitral valve interventions part 1: Systematic measurement methodology and inter-observer variability

  • Pascal Thériault-Lauzier
  • , Darren Mylotte
  • , Magdalena Dorfmeister
  • , Marco Spaziano
  • , Ali Andalib
  • , Samuel Mamane
  • , Michael Chetrit
  • , Philipp Blanke
  • , Renzo Cecere
  • , Jean Buithieu
  • , Giuseppe Martucci
  • , Didier Tchetche
  • , Thomas Modine
  • , Nicolas Van Mieghem
  • , Rüdiger Lange
  • , Stephan Windecker
  • , Luc Bilodeau
  • , Jonathon Leipsic
  • , Nicolo Piazza
  • McGill University
  • Merlin Park Regional Hospital
  • Technical University of Munich
  • University of British Columbia
  • Clinique Pasteur
  • CHRU Roger Salengro
  • Erasmus University Medical Center
  • Inselspital Universitatsspital

Research output: Contribution to journalArticlepeer-review

29 Scopus citations

Abstract

Aims: Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodality imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. Methods and results: A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. Conclusions: MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Original languageEnglish
Pages (from-to)e1011-e1020
JournalEuroIntervention
Volume12
Issue number8
DOIs
StatePublished - Oct 2016

Keywords

  • Congestive heart failure
  • Mitral regurgitation
  • Multi-slice computed tomography
  • Transcatheter heart valve
  • Transcatheter mitral valve replacement

Fingerprint

Dive into the research topics of 'Quantitative multi-slice computed tomography assessment of the mitral valvular complex for transcatheter mitral valve interventions part 1: Systematic measurement methodology and inter-observer variability'. Together they form a unique fingerprint.

Cite this