TY - JOUR
T1 - Quantitation of glutathione and its oxidation products in erythrocytes by multiple-label stable-isotope dilution
AU - Reinbold, Julia
AU - Koehler, Peter
AU - Rychlik, Michael
PY - 2014
Y1 - 2014
N2 - A multiple-label stable isotope dilution assay for quantifying glutathione (GSH), glutathione disulfide (GSSG), and glutathione sulfonic acid in erythrocytes was developed. As the internal standards, [13C 3,15N]glutathione, [13C4, 15N2]glutathione disulfide, and [13C 3,15N]glutathione sulfonic acid were used. Analytes and internal standards were detected by LC-MS/MS after derivatization of GSH with iodoacetic acid and dansylation of all compounds under study. The calibration functions for all analytes relative to their respective isotopologic standards revealed slopes close to 1.0 and negligible intercepts. As various labelings of the standards for GSH and GSSG were used, their simultaneous quantitation was possible, although GSH was partly oxidized to its disulfide during analysis. The degree of this artifact formation of GSSG was calculated from the abundance of the mixed disulfide formed from unlabeled GSH and its respective standard. Thus, the detected GSSG amount could be corrected for the artifact amount. In this way, the amount of GSSG in erythrocytes was found to be less than 0.5% of the GSH concentration. Similar to GSSG, the detected amount of glutathione sulfonic acid was found to be formed at least in part during the analytical process, but the degree could not be quantified.
AB - A multiple-label stable isotope dilution assay for quantifying glutathione (GSH), glutathione disulfide (GSSG), and glutathione sulfonic acid in erythrocytes was developed. As the internal standards, [13C 3,15N]glutathione, [13C4, 15N2]glutathione disulfide, and [13C 3,15N]glutathione sulfonic acid were used. Analytes and internal standards were detected by LC-MS/MS after derivatization of GSH with iodoacetic acid and dansylation of all compounds under study. The calibration functions for all analytes relative to their respective isotopologic standards revealed slopes close to 1.0 and negligible intercepts. As various labelings of the standards for GSH and GSSG were used, their simultaneous quantitation was possible, although GSH was partly oxidized to its disulfide during analysis. The degree of this artifact formation of GSSG was calculated from the abundance of the mixed disulfide formed from unlabeled GSH and its respective standard. Thus, the detected GSSG amount could be corrected for the artifact amount. In this way, the amount of GSSG in erythrocytes was found to be less than 0.5% of the GSH concentration. Similar to GSSG, the detected amount of glutathione sulfonic acid was found to be formed at least in part during the analytical process, but the degree could not be quantified.
KW - Artifact monitoring
KW - Erythrocytes
KW - Glutathione
KW - LC-MS/MS
KW - Multiple isotope labeling
KW - Stable isotope dilution assay
UR - http://www.scopus.com/inward/record.url?scp=84887375429&partnerID=8YFLogxK
U2 - 10.1016/j.ab.2013.09.029
DO - 10.1016/j.ab.2013.09.029
M3 - Article
C2 - 24120409
AN - SCOPUS:84887375429
SN - 0003-2697
VL - 445
SP - 41
EP - 48
JO - Analytical Biochemistry
JF - Analytical Biochemistry
IS - 1
ER -