Quantification of periprosthetic valve leakage with multiple regurgitation jets by magnetic resonance imaging

A. Pflaumer, M. Schwaiger, J. Hess, R. Lange, H. Stern

Research output: Contribution to journalArticlepeer-review

21 Scopus citations

Abstract

A patient with aortic prosthetic valve endocarditis required replacement of the prosthesis, After initial recovery, his left ventricular function gradually declined and echocardiography revealed minor paravalvular leakage and a cavern around the prosthesis. Magnetic resonance imaging was performed, flow-imaging and volume-based measurements showed high-grade paravalvular leakage of 45 and 58% regurgitant fraction, respectively. Intraoperatively, the dehiscence of more than half of the circumference of the aortic prosthesis was seen. This study shows that MRI can accurately assess even periprosthetic valve leakage with multiple regurgitation jets.

Original languageEnglish
Pages (from-to)593-594
Number of pages2
JournalPediatric Cardiology
Volume26
Issue number5
DOIs
StatePublished - Oct 2005

Keywords

  • Congenital heart disease
  • Magnetic resonance imaging
  • Periprosthetic valve leakage
  • Prosthetic valve

Fingerprint

Dive into the research topics of 'Quantification of periprosthetic valve leakage with multiple regurgitation jets by magnetic resonance imaging'. Together they form a unique fingerprint.

Cite this