Photon detectors for the HERA-B RICH

P. Križan, S. Korpar, M. Starič, A. Stanovnik, M. Cindro, R. Pestotnik, D. Škrk, A. Bulla, E. Michel, C. Oehser, P. Weyers, W. Schmidt-Parzefall, T. Hamacher, D. Broemmelsiek, J. Pyrlik

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Results of tests of different position-sensitive photon detectors for the HERA-B RICH are given. It is observed, that the CsI-MWPC cannot be routinely produced and maintained with sufficiently high quantum efficiency and that the TMAE detector loses anode wire gain too quickly. The third candidate, the H-6568 Hamamatsu multianode PMT, seems to meet all the requirements necessary for photon detection in the HERA-B RICH.

Original languageEnglish
Pages (from-to)146-149
Number of pages4
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume387
Issue number1-2
DOIs
StatePublished - 1 Mar 1997