Permeability, frost resistance and crack prevention of roller compacted concrete (RCC).

P. Sonnewald, R. Springenschmid

Research output: Contribution to journalArticlepeer-review

Abstract

Three test procedures for roller compacted concrete with respect to water permeability, frost resistance and crack prevention are described. For lower water permeability and enhanced frost resistance compacting water content of mixes must not be too low. For crack prevention a new test device (cracking frame) was constructed in order to obtain the unidirectional stress development of roller compacted concrete from the time of placing. By testing with the cracking frame, the viscoelastic properties of the materials at the time of early hydration are fully considered. The tests can be conducted at a wide variety of temperature and humidity conditions.(from paper)

Original languageEnglish
Pages (from-to)73-88
Number of pages16
JournalIN: TRANS. FIFTEENTH INT. CONGRESS ON LARGE DAMS, (LAUSANNE, SWITZERLAND: JUN. 24-28, 1985)
Volume2 , Paris, France, Int. Comm. on Large Dams, 1985, Question 57, Paper R.5
StatePublished - 1985

Fingerprint

Dive into the research topics of 'Permeability, frost resistance and crack prevention of roller compacted concrete (RCC).'. Together they form a unique fingerprint.