Percutaneous needle trephination. Experience in 200 cases

B. Meyer, K. Schaller, V. Rohde, W. Hassler

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

For many years percutaneous needle and classic burr-hole trephination with insertion of plastic catheters for external ventricular drainage are in use. The shortcomings of the conventional puncture needles were compensated for by the development of a modified instrument in recent years. In this prospective study we tried to define advantages and disadvantages of percutaneous ventriculostomy with this modified needle in a large number of patients. We treated and followed a total number of 200 patients with external ventricular drainage for various reasons (42% obstructive hydrocephalus, 27% haematocephalus, 11% malresorptive hydrocephalus, 11% elevated ICP and 9% infections). The ventriculostomy is performed - after percutaneous trepheication with a 1.5 mm drill and 1.2 mm needle under the local aesthesia as a bedside procedure. The modified blunt needle is provided with markings and a set screw which allows insertion to a prefixed depth and a sharp guide which is withdrawn after penetration of the dura. It is then bent rostrally and fixed by a plaster cast. The mean duration of drainage was 9 days (1-30 days). Mean operating time for the whole procedure including fixation and connection to the drainage system was 20 minutes. Overall complication rate was 13% (N=26). Two intracerebral haemorrhages (1%) occurred, of which one was caused by overdrainage. Five (3%) infections in primarily not infectious cases (N=182) were seen. Only one case of infection occurred without loosing of the needle on day 17. In 19 patients (10%) the needles had loosened. Fifteen times this complication was repaired in time and no infection occurred. The overall complication rate (13%) and the needle related risk of bleeding (0.5%) seem average. The true risk of infection with correct handling (0.5%) is very low despite the very long average duration of drainage. The main risk lies in the markedly high danger of loosening (10%), which entails a disproportionally high demand for nursing care. Nevertheless, we regard percutaneous needle trephination as the ventriculostomy method of choice because of its better practicability and low infection rate.

Original languageEnglish
Pages (from-to)232-235
Number of pages4
JournalActa Neurochirurgica
Volume127
Issue number3-4
DOIs
StatePublished - Sep 1994
Externally publishedYes

Keywords

  • Percutaneous needle trephination
  • complication
  • technique
  • ventriculostomy

Fingerprint

Dive into the research topics of 'Percutaneous needle trephination. Experience in 200 cases'. Together they form a unique fingerprint.

Cite this