Parallel operation of single-phase voltage source inverters: Modeling and control based on LMI constraints

Fabrício Saggin, Daniel Coutinho, Marcelo L. Heldwein

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

In this paper, a new model for droop-controlled single-phase voltage-source inverters (VSI) is presented. This model is based on dynamic phasors and includes load, line and filters dynamics, leading to an accurate model for static and transient behavior. Moreover, a controller design method based on linear matrix inequality (LMI) constraints is proposed ensuring not only stability, but also the system performance. Simulation results are provided to demonstrate the model validity and the effectiveness of the design methodology.

Original languageEnglish
Title of host publicationProceedings of the IECON 2016 - 42nd Annual Conference of the Industrial Electronics Society
PublisherIEEE Computer Society
Pages270-275
Number of pages6
ISBN (Electronic)9781509034741
DOIs
StatePublished - 21 Dec 2016
Externally publishedYes
Event42nd Conference of the Industrial Electronics Society, IECON 2016 - Florence, Italy
Duration: 24 Oct 201627 Oct 2016

Publication series

NameIECON Proceedings (Industrial Electronics Conference)

Conference

Conference42nd Conference of the Industrial Electronics Society, IECON 2016
Country/TerritoryItaly
CityFlorence
Period24/10/1627/10/16

Fingerprint

Dive into the research topics of 'Parallel operation of single-phase voltage source inverters: Modeling and control based on LMI constraints'. Together they form a unique fingerprint.

Cite this