P05 imaging beamline at petra III - First results

Imke Greving, Fabian Wilde, Malte Ogurreck, Julia Herzen, Jörg U. Hammel, Alexander Hipp, Frank Friedrich, Lars Lottermoser, Thomas Dose, Hilmar Burmester, Martin Müller, Felix Beckmann

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

69 Scopus citations

Abstract

The imaging beamline (IBL/P05) operated by Helmholtz Zentrum Geesthacht (HZG) at the DESY PETRA III storage ring consists of two experimental stations: A micro-tomography and a nano-tomography end station. Here an overview of the experimental setups and the data acquisition will be given. In addition some first results out of the wide range of applications using the micro tomography station at P05 will be shown. Furthermore, we present first results of the nano-tomography end station. These were obtained with an x-ray microscopy setup, which currently operates at energies of 17.4 and 30 keV using polymer compound refractive lenses (CRLs) and rolled prism lenses. Taken together these results clearly show the high potential of the newly built imaging beamline IBL.

Original languageEnglish
Title of host publicationDevelopments in X-Ray Tomography IX
EditorsStuart R. Stock
PublisherSPIE
ISBN (Electronic)9781628412390
DOIs
StatePublished - 2014
EventDevelopments in X-Ray Tomography IX - San Diego, United States
Duration: 18 Aug 201420 Aug 2014

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume9212
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

ConferenceDevelopments in X-Ray Tomography IX
Country/TerritoryUnited States
CitySan Diego
Period18/08/1420/08/14

Keywords

  • Beamline
  • CRL
  • Imaging
  • Lenses
  • Tomography

Fingerprint