P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: The microfocus endstation

Adeline Buffet, André Rothkirch, Ralph Döhrmann, Volker Körstgens, Mottakin M. Abul Kashem, Jan Perlich, Gerd Herzog, Matthias Schwartzkopf, Rainer Gehrke, Peter Müller-Buschbaum, Stephan V. Roth

Research output: Contribution to journalArticlepeer-review

297 Scopus citations

Abstract

The P03 beamline, also called the microfocus and nanofocus X-ray scattering (MiNaXS) beamline, exploits the excellent photon beam properties of the low-emittance source PETRA III to provide a microfocused/nanofocused beam with ultra-high intensity for time-resolved X-ray scattering experiments. The beamline has been designed to perform X-ray scattering in both transmission and reflection geometries. The microfocus endstation started user operation in May 2011. An overview of the beamline status and of some representative results highlighting the performance of the microfocus endstation at MiNaXS are given.

Original languageEnglish
Pages (from-to)647-653
Number of pages7
JournalJournal of Synchrotron Radiation
Volume19
Issue number4
DOIs
StatePublished - Jul 2012

Keywords

  • X-ray scattering
  • kinetic studies
  • microfocus
  • nanocomposites

Fingerprint

Dive into the research topics of 'P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: The microfocus endstation'. Together they form a unique fingerprint.

Cite this