TY - GEN
T1 - Official measurement protocol and accuracy results for an optical surgical navigation system (NPU)
AU - Wittmann, Wolfgang
AU - Wenger, Thomas
AU - Loewe, Erik
AU - Lueth, Tim C.
PY - 2011
Y1 - 2011
N2 - Image-guided surgical navigation is on the rise in many different areas of modern medicine and is already an established standard in some disciplines like ear nose and throat (ENT) or maxillofacial surgery. When evaluating surgical navigation systems the absolute accuracy of the device is of major concern to the surgeon. The following work presents two different ways of measuring the accuracy of surgical navigation systems using the example of the KARL STORZ Navigation Panel Unit (NPU). According to these protocols the FDA approval of the NPU navigation system was prepared. In a first series of experiments the accuracy under realistic surgical conditions is evaluated with a phantom of a human head, which is manufactured in rapid-prototyping processes. In another series of experiments a custom registration board is used, which provides means to evaluate the accuracy under optimal conditions and also allows further measurements regarding the registration error, that are not possible with the phantom. In the experiments an accuracy of 1.44 mm 0.18 mm was measured in the surgical setup and 0.63 mm 0.07 mm under ideal conditions.
AB - Image-guided surgical navigation is on the rise in many different areas of modern medicine and is already an established standard in some disciplines like ear nose and throat (ENT) or maxillofacial surgery. When evaluating surgical navigation systems the absolute accuracy of the device is of major concern to the surgeon. The following work presents two different ways of measuring the accuracy of surgical navigation systems using the example of the KARL STORZ Navigation Panel Unit (NPU). According to these protocols the FDA approval of the NPU navigation system was prepared. In a first series of experiments the accuracy under realistic surgical conditions is evaluated with a phantom of a human head, which is manufactured in rapid-prototyping processes. In another series of experiments a custom registration board is used, which provides means to evaluate the accuracy under optimal conditions and also allows further measurements regarding the registration error, that are not possible with the phantom. In the experiments an accuracy of 1.44 mm 0.18 mm was measured in the surgical setup and 0.63 mm 0.07 mm under ideal conditions.
UR - http://www.scopus.com/inward/record.url?scp=84862265266&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2011.6090291
DO - 10.1109/IEMBS.2011.6090291
M3 - Conference contribution
C2 - 22254540
AN - SCOPUS:84862265266
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 1237
EP - 1240
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -