Neutron dark-field tomography

M. Strobl, C. Grünzweig, A. Hilger, I. Manke, N. Kardjilov, C. David, F. Pfeiffer

Research output: Contribution to journalArticlepeer-review

153 Scopus citations

Abstract

We report how a grating interferometer yields neutron dark-field scatter images for tomographic investigations. The image contrast is based on ultrasmall-angle scattering. It provides otherwise inaccessible spatially resolved information about the distribution of micrometer and submicrometer sized structural formations. Three complementary sets of tomographic data corresponding to attenuation, differential phase, and small-angle scattering can be obtained from one measurement. The method is compatible with conventional imaging and provides significantly higher efficiency than existing techniques.

Original languageEnglish
Article number123902
JournalPhysical Review Letters
Volume101
Issue number12
DOIs
StatePublished - 15 Sep 2008
Externally publishedYes