Skip to main navigation Skip to search Skip to main content

Neointimal Modification With Scoring Balloon and Efficacy of Drug-Coated Balloon Therapy in Patients With Restenosis in Drug-Eluting Coronary Stents: A Randomized Controlled Trial

  • ISAR-DESIRE 4 Investigators
  • Technical University of Munich
  • Herzzentrum Segeberger Kliniken
  • Krankenhaus Landshut-Achdorf
  • Partner Site Munich Heart Alliance

Research output: Contribution to journalArticlepeer-review

165 Scopus citations

Abstract

Objectives The aim of this study was to compare neointimal modification with scoring balloon pre-dilation before drug-coated balloon (DCB) versus DCB standard therapy in patients presenting with drug-eluting stent (DES) restenosis. Background DCB angioplasty for the treatment of coronary drug-eluting stent restenosis has demonstrated encouraging results. The efficacy of DCB treatment relies on rapid initial drug transfer and tissue retention of the antiproliferative drug. Neointimal modification with scoring balloon pre-dilation may enhance the efficacy of DCB therapy. Methods In this randomized, open-label, active-controlled trial, 252 patients with clinically significant DES restenosis were enrolled at 4 centers in Germany. Patients undergoing DCB angioplasty were randomly assigned to treatment with scoring balloon pre-dilation or standard therapy. The primary endpoint of the study was in-segment percentage diameter stenosis on 6- to 8-month follow-up angiography. The secondary endpoints included binary angiographic restenosis and late lumen loss on follow-up angiography, the combined incidence of death or myocardial infarction, target lesion revascularization, and target lesion thrombosis at 1 year. Results Follow-up angiographic data at 6 to 8 months were available for 203 patients (80.6%). Scoring balloon pre-dilation compared with standard therapy showed significantly lower rates with respect to the primary endpoint (35.0 ± 16.8% vs. 40.4 ± 21.4%; p = 0.047) and binary angiographic restenosis (18.5% vs. 32.0%; p = 0.026). Late lumen loss was numerically lower after scoring balloon pre-dilation compared with standard therapy (0.31 ± 59 mm vs. 0.41 ± 0.74 mm; p = 0.27). There was no difference between the groups in the incidence of death or myocardial infarction (4.0% vs. 3.4%; p = 0.73). Scoring balloon versus standard therapy showed comparable rates of target lesion revascularization (16.2% vs. 21.8%; p = 0.26). No target lesion thrombosis occurred out to 1 year. Conclusions In patients presenting with drug-eluting stent restenosis, neointimal modification with scoring balloon improves the antirestenotic efficacy of DCB therapy.

Original languageEnglish
Pages (from-to)1332-1340
Number of pages9
JournalJACC: Cardiovascular Interventions
Volume10
Issue number13
DOIs
StatePublished - 10 Jul 2017

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • drug-coated balloon
  • drug-eluting stent(s)
  • randomized trial
  • restenosis
  • scoring balloon

Fingerprint

Dive into the research topics of 'Neointimal Modification With Scoring Balloon and Efficacy of Drug-Coated Balloon Therapy in Patients With Restenosis in Drug-Eluting Coronary Stents: A Randomized Controlled Trial'. Together they form a unique fingerprint.

Cite this