MINDERUNG VON PXDD/F-EMISSIONEN. NIEDERTEMPERATUR-PARTIKELABSCHEIDUNG IN VERBRENNUNGSANLAGEN: FUGAZITATSBERECHNUNGEN

Translated title of the contribution: Reduction of PXDD/F emissions. Low-temperature-separation of flyash in incinerators: Fugacity calculations

K. W. Schramm, H. Fiedler, O. Hutzinger

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

The emission of PXDD-F from incinerators depends on the partition between stackgas and flyash. Fugacity calculations show that the separation of the flyash at low temperatures lowers the total emission up to hundred fold.

Translated title of the contributionReduction of PXDD/F emissions. Low-temperature-separation of flyash in incinerators: Fugacity calculations
Original languageGerman