N2 - The described in vitro test system for allergy diagnosis is based on microscope glass slides activated with (3-glycidyloxypropyl)trimethoxysilane. Allergen solutions are immobilized as small droplets (∼10 nL) on the activated glass slides with a piezoelectric arrayer. In contrast to other tests for specific IgE, such as Pharmacia CAP FEIA, AlaSTAT, or FAST, only a 25-μL serum sample is needed for the screening of allergen-specific IgE against a multitude of allergens and the test can be performed in less than 1 h. Compared with multiallergen dipstick screening tests (e.g., IgEquick, CMG Immunodot) based on multiallergen-coated nitrocellulose strips, the measurement of the microarray-based system can be performed automatically. The chemiluminescence intensities are detected with a sensitive CCD camera. Allergen extracts and recombinant/purified allergens (24 preparations) have been used on the same modified surface for the screening of allergen-specific IgE. With these disposable microarray slides, it is possible to distinguish between patients with and without elevated levels of allergen-specific IgE. Repeated measurements of serum samples demonstrated a sufficient reproducibility. Detection limits (μg/L) of 0.35 (r Bet v1), 0.16 (PLA2), and 1.9 (Der p1) were achieved.
AB - The described in vitro test system for allergy diagnosis is based on microscope glass slides activated with (3-glycidyloxypropyl)trimethoxysilane. Allergen solutions are immobilized as small droplets (∼10 nL) on the activated glass slides with a piezoelectric arrayer. In contrast to other tests for specific IgE, such as Pharmacia CAP FEIA, AlaSTAT, or FAST, only a 25-μL serum sample is needed for the screening of allergen-specific IgE against a multitude of allergens and the test can be performed in less than 1 h. Compared with multiallergen dipstick screening tests (e.g., IgEquick, CMG Immunodot) based on multiallergen-coated nitrocellulose strips, the measurement of the microarray-based system can be performed automatically. The chemiluminescence intensities are detected with a sensitive CCD camera. Allergen extracts and recombinant/purified allergens (24 preparations) have been used on the same modified surface for the screening of allergen-specific IgE. With these disposable microarray slides, it is possible to distinguish between patients with and without elevated levels of allergen-specific IgE. Repeated measurements of serum samples demonstrated a sufficient reproducibility. Detection limits (μg/L) of 0.35 (r Bet v1), 0.16 (PLA2), and 1.9 (Der p1) were achieved.
UR - http://www.scopus.com/inward/record.url?scp=0346037126&partnerID=8YFLogxK
U2 - 10.1021/ac026016k
DO - 10.1021/ac026016k
M3 - Article
C2 - 12585484
AN - SCOPUS:0346037126
SN - 0003-2700
VL - 75
SP - 556
EP - 562
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 3
ER -