T1 - Mdct-based finite element analysis for the prediction of functional spine unit strength—an in vitro study
AU - Rayudu, Nithin Manohar
AU - Baum, Thomas
AU - Kirschke, Jan S.
AU - Subburaj, Karupppasamy
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/10/1
Y1 - 2021/10/1
N2 - (1) Objective: This study aimed to analyze the effect of ligaments on the strength of functional spine unit (FSU) assessed by finite element (FE) analysis of anatomical models developed from multi-detector computed tomography (MDCT) data. (2) Methods: MDCT scans for cadaveric specimens were acquired from 16 donors (7 males, mean age of 84.29 ± 6.06 years and 9 females, mean age of 81.00 ± 11.52 years). Two sets of FSU models (three vertebrae + two disks), one with and another without (w/o) ligaments, were generated. The vertebrae were segmented semi-automatically, intervertebral disks (IVD) were generated manually, and ligaments were modeled based on the anatomical location. FE-predicted failure loads of FSU models (with and w/o ligaments) were compared with the experimental failure loads obtained from the uniaxial biomechanical test of specimens. (3) Results: The mean and standard deviation of the experimental failure load of FSU specimens was 3513 ± 1029 N, whereas of FE-based failure loads were 2942 ± 943 N and 2537 ± 929 N for FSU models with ligaments and without ligament attachments, respectively. A good correlation (ρ = 0.79, and ρ = 0.75) was observed between the experimental and FE-based failure loads for the FSU model with and with ligaments, respectively. (4) Conclusions: The FE-based FSU model can be used to determine bone strength, and the ligaments seem to have an effect on the model accuracy for the failure load calculation; further studies are needed to understand the contribution of ligaments.
AB - (1) Objective: This study aimed to analyze the effect of ligaments on the strength of functional spine unit (FSU) assessed by finite element (FE) analysis of anatomical models developed from multi-detector computed tomography (MDCT) data. (2) Methods: MDCT scans for cadaveric specimens were acquired from 16 donors (7 males, mean age of 84.29 ± 6.06 years and 9 females, mean age of 81.00 ± 11.52 years). Two sets of FSU models (three vertebrae + two disks), one with and another without (w/o) ligaments, were generated. The vertebrae were segmented semi-automatically, intervertebral disks (IVD) were generated manually, and ligaments were modeled based on the anatomical location. FE-predicted failure loads of FSU models (with and w/o ligaments) were compared with the experimental failure loads obtained from the uniaxial biomechanical test of specimens. (3) Results: The mean and standard deviation of the experimental failure load of FSU specimens was 3513 ± 1029 N, whereas of FE-based failure loads were 2942 ± 943 N and 2537 ± 929 N for FSU models with ligaments and without ligament attachments, respectively. A good correlation (ρ = 0.79, and ρ = 0.75) was observed between the experimental and FE-based failure loads for the FSU model with and with ligaments, respectively. (4) Conclusions: The FE-based FSU model can be used to determine bone strength, and the ligaments seem to have an effect on the model accuracy for the failure load calculation; further studies are needed to understand the contribution of ligaments.
KW - Bone strength
KW - Finite element analysis
KW - Functional spine unit
KW - Multidetector computed tomography
UR - http://www.scopus.com/inward/record.url?scp=85116417739&partnerID=8YFLogxK
U2 - 10.3390/ma14195791
DO - 10.3390/ma14195791
M3 - Article
AN - SCOPUS:85116417739
SN - 1996-1944
VL - 14
JO - Materials
JF - Materials
IS - 19
M1 - 5791
ER -