Magnetic resonance imaging-guided balloon angioplasty of coarctation of the aorta: A pilot study

Julia J. Krueger, Peter Ewert, Sevim Yilmaz, Dinah Gelernter, Björn Peters, Klaus Pietzner, Axel Bornstedt, Bernhard Schnackenburg, Hashim Abdul-Khaliq, Eckart Fleck, Eike Nagel, Felix Berger, Titus Kuehne

Research output: Contribution to journalArticlepeer-review

69 Scopus citations

Abstract

Background - MRI guidance of percutaneous transluminal balloon angioplasty (PTA) of aortic coarctation (CoA) would be desirable for continuous visualization of anatomy and to eliminate x-ray exposure. The aim of this study was (1) to determine the suitability of MRI-controlled PTA using the iron oxide-based contrast medium Resovist (ferucarbotran) for catheter visualization and (2) to subsequently apply this technique in a pilot study with patients with CoA. Methods and Results - The MRI contrast-to-noise ratio and artifact behavior of Resovist-treated balloon catheters was optimized in in vitro and animal experiments (pigs). In 5 patients, anatomy of the CoA was evaluated before and after intervention with high-re solution respiratory-navigated 3D MRI and multiphase cine MRI. Position monitoring of Resovist-treated catheters was realized with interactive real-time MRI. Aortic pressures were continuously recorded. Conventional catheterization was performed before and after MRI to confirm interventional success. During MRI, catheters filled with 25 μmol of iron particles per milliliter of Resovist produced good signal contrast between catheters and their background anatomy but no image distortion due to susceptibility artifacts. All MRI procedures were performed successfully in the patient study. There was excellent agreement between the diameters of CoA and pressure gradients as measured during MRI and conventional catheterization. In 4 patients, PTA resulted in substantial widening of the CoA and a decrease in pressure gradients. In 1 patient, PTA was ineffective. Conclusions - The MRI method described represents a potential alternative to conventional x-ray fluoroscopy for catheter-based treatment of patients with CoA.

Original languageEnglish
Pages (from-to)1093-1100
Number of pages8
JournalCirculation
Volume113
Issue number8
DOIs
StatePublished - Feb 2006
Externally publishedYes

Keywords

  • Angioplasty
  • Balloon
  • Coarctation
  • Contrast media
  • Magnetic resonance imaging

Fingerprint

Dive into the research topics of 'Magnetic resonance imaging-guided balloon angioplasty of coarctation of the aorta: A pilot study'. Together they form a unique fingerprint.

Cite this