Lesion-to-background ratio threshold value of SUVmax of simultaneous [68Ga]Ga-PSMA-11 PET/MRI imaging in patients with prostate cancer

Jing Zhao, Bernd Hamm, Winfried Brenner, Marcus R. Makowski

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Purpose: This study aimed to calculate an applicable relative ratio threshold value instead of the absolute threshold value for simultaneous 68Ga prostate-specific membrane antigen/positron emission tomography ([68Ga]Ga-PSMA-11 PET) in patients with prostate cancer (PCa). Materials and methods: Our study evaluated thirty-two patients and 170 focal prostate lesions. Lesions are classified into groups according to Prostate Imaging Reporting and Data System (PI-RADS). Standardized uptake values maximum (SUVmax), corresponding lesion-to-background ratios (LBRs) of SUVmax, and LBR distributions of each group were measured based on regions of interest (ROI). We examined LBR with receiver operating characteristic analysis to determine threshold values for differentiation between multiparametric magnetic resonance imaging (mpMRI)-positive and mpMRI-negative lesions. Results: We analyzed a total of 170 focal prostate lesions. Lesions number of PI-RADS 2 to 5 was 70, 16, 46, and 38. LBR of SUVmax of each PI-RADS scores was 1.5 (0.9, 2.4), 2.5 (1.6, 3.4), 3.7 (2.6, 4.8), and 6.7 (3.5, 12.7). Based on an optimal threshold ratio of 2.5 to be exceeded, lesions could be classified into MRI-positive lesion on [68Ga]Ga-PSMA PET with a sensitivity of 85.2%, a specificity of 72.0%, with the corresponding area under the receiver operating characteristic curve (AUC) of 0.83, p < 0.001. This value matches the imaging findings better. Conclusion: The ratio threshold value of SUVmax, LBR, has improved clinical and research applicability compared with the absolute value of SUVmax. A higher threshold value than the background’s uptake can dovetail the imaging findings on MRI better. It reduces the bias from using absolute background uptake value as the threshold value.

Original languageEnglish
Article number137
JournalInsights into Imaging
Volume11
Issue number1
DOIs
StatePublished - Dec 2020

Keywords

  • Multiparametric MRI
  • PSMA
  • Prostate cancer
  • SUVmax
  • [Ga]Ga-PSMA PET/MRI

Fingerprint

Dive into the research topics of 'Lesion-to-background ratio threshold value of SUVmax of simultaneous [68Ga]Ga-PSMA-11 PET/MRI imaging in patients with prostate cancer'. Together they form a unique fingerprint.

Cite this