TY - JOUR
T1 - Learning-based quality control for cardiac MR images
AU - Tarroni, Giacomo
AU - Oktay, Ozan
AU - Bai, Wenjia
AU - Schuh, Andreas
AU - Suzuki, Hideaki
AU - Passerat-Palmbach, Jonathan
AU - De Marvao, Antonio
AU - O'Regan, Declan P.
AU - Cook, Stuart
AU - Glocker, Ben
AU - Matthews, Paul M.
AU - Rueckert, Daniel
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/5
Y1 - 2019/5
N2 - The effectiveness of a cardiovascular magnetic resonance (CMR) scan depends on the ability of the operator to correctly tune the acquisition parameters to the subject being scanned and on the potential occurrence of imaging artifacts, such as cardiac and respiratory motion. In the clinical practice, a quality control step is performed by visual assessment of the acquired images; however, this procedure is strongly operator-dependent, cumbersome, and sometimes incompatible with the time constraints in clinical settings and large-scale studies. We propose a fast, fully automated, and learning-based quality control pipeline for CMR images, specifically for short-axis image stacks. Our pipeline performs three important quality checks: 1) heart coverage estimation; 2) inter-slice motion detection; 3) image contrast estimation in the cardiac region. The pipeline uses a hybrid decision forest method-integrating both regression and structured classification models-to extract landmarks and probabilistic segmentation maps from both long- A nd short-axis images as a basis to perform the quality checks. The technique was tested on up to 3000 cases from the UK Biobank and on 100 cases from the UK Digital Heart Project and validated against manual annotations and visual inspections performed by expert interpreters. The results show the capability of the proposed pipeline to correctly detect incomplete or corrupted scans (e.g., on UK Biobank, sensitivity and specificity, respectively, 88% and 99% for heart coverage estimation and 85% and 95% for motion detection), allowing their exclusion from the analyzed dataset or the triggering of a new acquisition.
AB - The effectiveness of a cardiovascular magnetic resonance (CMR) scan depends on the ability of the operator to correctly tune the acquisition parameters to the subject being scanned and on the potential occurrence of imaging artifacts, such as cardiac and respiratory motion. In the clinical practice, a quality control step is performed by visual assessment of the acquired images; however, this procedure is strongly operator-dependent, cumbersome, and sometimes incompatible with the time constraints in clinical settings and large-scale studies. We propose a fast, fully automated, and learning-based quality control pipeline for CMR images, specifically for short-axis image stacks. Our pipeline performs three important quality checks: 1) heart coverage estimation; 2) inter-slice motion detection; 3) image contrast estimation in the cardiac region. The pipeline uses a hybrid decision forest method-integrating both regression and structured classification models-to extract landmarks and probabilistic segmentation maps from both long- A nd short-axis images as a basis to perform the quality checks. The technique was tested on up to 3000 cases from the UK Biobank and on 100 cases from the UK Digital Heart Project and validated against manual annotations and visual inspections performed by expert interpreters. The results show the capability of the proposed pipeline to correctly detect incomplete or corrupted scans (e.g., on UK Biobank, sensitivity and specificity, respectively, 88% and 99% for heart coverage estimation and 85% and 95% for motion detection), allowing their exclusion from the analyzed dataset or the triggering of a new acquisition.
KW - Image quality assessment
KW - heart
KW - magnetic resonance imaging
KW - motion compensation and analysis
UR - http://www.scopus.com/inward/record.url?scp=85056197379&partnerID=8YFLogxK
U2 - 10.1109/TMI.2018.2878509
DO - 10.1109/TMI.2018.2878509
M3 - Article
C2 - 30403623
AN - SCOPUS:85056197379
SN - 0278-0062
VL - 38
SP - 1127
EP - 1138
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 5
M1 - 8519790
ER -