N2 - The influence of relative air humidity on the surface charge decay on epoxy resin insulators initially charged by DC corona and on their surface resistivity is investigated at room temperature. It has been observed, that surface resistivity of the epoxy resin insulators decreases significantly at higher relative humidity. Thus, at higher relative humidity surface charge decay is dominated by electric conduction along the insulator surface. This effect has been verified by both, measurement and simulation of the surface charge decay.
AB - The influence of relative air humidity on the surface charge decay on epoxy resin insulators initially charged by DC corona and on their surface resistivity is investigated at room temperature. It has been observed, that surface resistivity of the epoxy resin insulators decreases significantly at higher relative humidity. Thus, at higher relative humidity surface charge decay is dominated by electric conduction along the insulator surface. This effect has been verified by both, measurement and simulation of the surface charge decay.
KW - Solid insulator
KW - Surface charge decay
KW - Surface resistivity
UR - https://www.scopus.com/pages/publications/71049179924
U2 - 10.1109/ICPADM.2009.5252237
DO - 10.1109/ICPADM.2009.5252237
M3 - Conference contribution
AN - SCOPUS:71049179924
SN - 9781424443680
T3 - Proceedings of the IEEE International Conference on Properties and Applications of Dielectric Materials
SP - 883
EP - 886
BT - 2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials, ICPADM 2009
T2 - 2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials, ICPADM 2009
Y2 - 19 July 2009 through 23 July 2009
ER -