TY - JOUR
T1 - Influence of maximum power output on speech understanding with bone anchored hearing systems
AU - Gawliczek, Tom
AU - Wimmer, Wilhelm
AU - Caversaccio, Marco
AU - Kompis, Martin
N1 - Publisher Copyright:
© 2019, © 2019 Acta Oto-Laryngologica AB (Ltd).
PY - 2020/3/3
Y1 - 2020/3/3
N2 - Background: Maximum power output (MPO) levels of bone anchored hearing systems (BAHS) vary between different devices, but are significantly lower than those of conventional hearing aids, potentially limiting speech understanding. Aims/objectives: To investigate, how MPO influences speech understanding in quiet and in noise in BAHS users. Materials and methods: 12 adult BAHS users with a bilateral conductive hearing loss and additional sensorineural hearing components between 4 and 45 dB (500–4000 Hz) participated in the study. Speech understanding was measured at 65 dB in quiet and in noise with 4 different MPO level settings, covering the approximate range of MPOs found in currently available BAHS devices. Results: Speech understanding in quiet and in noise decreased with increasing sensorineural hearing loss. MPOs levels did not influence speech understanding in quiet significantly. In contrast, speech understanding in noise was better with higher MPOs (average improvement in signal-to-noise ratio +3.2 dB, p <.001), but only if the sensorineural hearing loss component was above approximately 35 dB. Conclusions and significance: At normal conversational levels, higher MPOs have little or no influence on speech understanding in quiet with BAHS. However, they can improve speech understanding in noise for users with additional sensorineural hearing loss.
AB - Background: Maximum power output (MPO) levels of bone anchored hearing systems (BAHS) vary between different devices, but are significantly lower than those of conventional hearing aids, potentially limiting speech understanding. Aims/objectives: To investigate, how MPO influences speech understanding in quiet and in noise in BAHS users. Materials and methods: 12 adult BAHS users with a bilateral conductive hearing loss and additional sensorineural hearing components between 4 and 45 dB (500–4000 Hz) participated in the study. Speech understanding was measured at 65 dB in quiet and in noise with 4 different MPO level settings, covering the approximate range of MPOs found in currently available BAHS devices. Results: Speech understanding in quiet and in noise decreased with increasing sensorineural hearing loss. MPOs levels did not influence speech understanding in quiet significantly. In contrast, speech understanding in noise was better with higher MPOs (average improvement in signal-to-noise ratio +3.2 dB, p <.001), but only if the sensorineural hearing loss component was above approximately 35 dB. Conclusions and significance: At normal conversational levels, higher MPOs have little or no influence on speech understanding in quiet with BAHS. However, they can improve speech understanding in noise for users with additional sensorineural hearing loss.
KW - Bone anchored devices bone conduction speech in noise mixed hearing loss
UR - http://www.scopus.com/inward/record.url?scp=85076422396&partnerID=8YFLogxK
U2 - 10.1080/00016489.2019.1697464
DO - 10.1080/00016489.2019.1697464
M3 - Article
C2 - 31825702
AN - SCOPUS:85076422396
SN - 0001-6489
VL - 140
SP - 225
EP - 229
JO - Acta Oto-Laryngologica
JF - Acta Oto-Laryngologica
IS - 3
ER -