TY - JOUR
T1 - Incidental findings in multislice computed tomography prior to transcatheter aortic valve implantation
T2 - frequency, clinical relevance and outcome
AU - Trenkwalder, Teresa
AU - Lahmann, Anna Lena
AU - Nowicka, Magdalena
AU - Pellegrini, Costanza
AU - Rheude, Tobias
AU - Mayr, N. Patrick
AU - Voss, Stephanie
AU - Bleiziffer, Sabine
AU - Lange, Rüdiger
AU - Joner, Michael
AU - Kasel, Albert M.
AU - Kastrati, Adnan
AU - Schunkert, Heribert
AU - Husser, Oliver
AU - Hadamitzky, Martin
AU - Hengstenberg, Christian
N1 - Publisher Copyright:
© 2018, Springer Science+Business Media B.V., part of Springer Nature.
PY - 2018/6/1
Y1 - 2018/6/1
N2 - Multislice computed tomography (MSCT) has emerged as the mainstay in patients planned for transcatheter aortic valve implantation (TAVI). Incidental findings (IF) in MSCT are common. However, the exact incidence, clinical relevance and further consequences of IF are unclear and it is controversial whether IF adversely affect patients’ outcome. We analyzed MSCT data of 1050 patients screened for TAVI between January 2011 and December 2014. Median follow-up of patients was 20 months. In total, 3194 IF were identified, which were classified into clinically non-relevant IF (2872, 90%) and clinically relevant IF (322, 10%). In 25% of patients (258/1050) at least one clinically relevant IF was present. Age (80 ± 7 vs. 80 ± 7 years; p = 0.198) and EuroSCORE II (3.6% [2.1–5.7] vs. 3.6% [2.1–5.9]; p = 0.874) was similar between patients with and without a clinically relevant IF. TAVI was performed less frequently in patients with a clinically relevant IF (76% vs. 85%; p < 0.001), with more patients receiving surgical aortic valve replacement in that group (14% vs. 11%; p = 0.042), possibly due to the high rate of incidental aneurysms of the ascending aorta (n = 48). If TAVI was performed mortality did not differ (30-days: 4% vs. 3%; p = 0.339, 1-year: 11% vs. 14%; p = 0.226) between patients with and without a clinically relevant IF. Our study is the largest study to analyze prevalence, clinical relevance and therapeutic consequences of IF during screening for TAVI. IF in pre-procedural MSCT are common and clinically relevant in one-quarter of patients. However, these findings had no impact on overall mortality.
AB - Multislice computed tomography (MSCT) has emerged as the mainstay in patients planned for transcatheter aortic valve implantation (TAVI). Incidental findings (IF) in MSCT are common. However, the exact incidence, clinical relevance and further consequences of IF are unclear and it is controversial whether IF adversely affect patients’ outcome. We analyzed MSCT data of 1050 patients screened for TAVI between January 2011 and December 2014. Median follow-up of patients was 20 months. In total, 3194 IF were identified, which were classified into clinically non-relevant IF (2872, 90%) and clinically relevant IF (322, 10%). In 25% of patients (258/1050) at least one clinically relevant IF was present. Age (80 ± 7 vs. 80 ± 7 years; p = 0.198) and EuroSCORE II (3.6% [2.1–5.7] vs. 3.6% [2.1–5.9]; p = 0.874) was similar between patients with and without a clinically relevant IF. TAVI was performed less frequently in patients with a clinically relevant IF (76% vs. 85%; p < 0.001), with more patients receiving surgical aortic valve replacement in that group (14% vs. 11%; p = 0.042), possibly due to the high rate of incidental aneurysms of the ascending aorta (n = 48). If TAVI was performed mortality did not differ (30-days: 4% vs. 3%; p = 0.339, 1-year: 11% vs. 14%; p = 0.226) between patients with and without a clinically relevant IF. Our study is the largest study to analyze prevalence, clinical relevance and therapeutic consequences of IF during screening for TAVI. IF in pre-procedural MSCT are common and clinically relevant in one-quarter of patients. However, these findings had no impact on overall mortality.
KW - Aortic valve stenosis
KW - Incidental findings
KW - Multislice computed tomography
KW - TAVI
UR - http://www.scopus.com/inward/record.url?scp=85042237537&partnerID=8YFLogxK
U2 - 10.1007/s10554-018-1305-5
DO - 10.1007/s10554-018-1305-5
M3 - Article
C2 - 29468355
AN - SCOPUS:85042237537
SN - 1569-5794
VL - 34
SP - 985
EP - 992
JO - International Journal of Cardiovascular Imaging
JF - International Journal of Cardiovascular Imaging
IS - 6
ER -