TY - JOUR
T1 - Improved visualisation of hepatic metastases in gadoxetate disodium-enhanced MRI
T2 - Potential of contrast-optimised (phase-sensitive) inversion recovery imaging
AU - Fahlenkamp, Ute Lina
AU - Engel, Günther
AU - Adams, Lisa Christine
AU - Böker, Sarah Maria
AU - Anh, Minh Huynh
AU - Wagner, Moritz
AU - Hamm, Bernd
AU - Makowski, Marcus Richard
N1 - Publisher Copyright:
© 2019 Fahlenkamp et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2019/3
Y1 - 2019/3
N2 - Background Detection of metastases can have a significant impact on therapy. Nevertheless, even in gadoxetate disodium-enhanced MR scans, very small hepatic metastases may be difficult to see. Purpose To investigate the potential of a contrast-optimised (phase-sensitive) inversion recovery MR sequence in gadoxetate disodium-enhanced scans for detection of hepatic metastases. Materials and methods With institutional review board approval and after written informed consent, 40 patients (18 male, 22 female) with suspected or known hepatic metastases were examined on a 1.5 T MR system. A T1-weighted gradient-echo volumetric-interpolated-breath-hold (VIBE) sequence was acquired as part of the standard imaging protocol 20 minutes after administration of gadoxetate disodium. Additionally, an IR sequence was acquired with an inversion time to suppress native signal from metastases. Overall image quality and delineation of lesions were assessed on VIBE as well as on magnitude-reconstructed (MAG) and phase-sensitive IR (PSIR) sequences. Lesion-to-liver contrast (LLC) was compared between VIBE and MAG images. Results Overall image quality was high in both VIBE and MAG IR sequences (VIBE 4.275; MAG 4.313), yet significantly lower in PSIR (4.038). Subjective delineation of lesions was higher on MAG and PSIR images compared to VIBE in all size groups with an overall statistically significant difference for VIBE vs. MAG vs. PSIR (p < .001) in the variance analysis. Mean LLC was 0.35±0.01 for VIBE sequences, and 0.73±0.01 for MAG. Conclusion Contrast-optimised PSIR seems to improve imaging characteristics of hepatic metastases in gadoxetate disodium-enhanced scans compared to T1 gradient-echo VIBE sequences.
AB - Background Detection of metastases can have a significant impact on therapy. Nevertheless, even in gadoxetate disodium-enhanced MR scans, very small hepatic metastases may be difficult to see. Purpose To investigate the potential of a contrast-optimised (phase-sensitive) inversion recovery MR sequence in gadoxetate disodium-enhanced scans for detection of hepatic metastases. Materials and methods With institutional review board approval and after written informed consent, 40 patients (18 male, 22 female) with suspected or known hepatic metastases were examined on a 1.5 T MR system. A T1-weighted gradient-echo volumetric-interpolated-breath-hold (VIBE) sequence was acquired as part of the standard imaging protocol 20 minutes after administration of gadoxetate disodium. Additionally, an IR sequence was acquired with an inversion time to suppress native signal from metastases. Overall image quality and delineation of lesions were assessed on VIBE as well as on magnitude-reconstructed (MAG) and phase-sensitive IR (PSIR) sequences. Lesion-to-liver contrast (LLC) was compared between VIBE and MAG images. Results Overall image quality was high in both VIBE and MAG IR sequences (VIBE 4.275; MAG 4.313), yet significantly lower in PSIR (4.038). Subjective delineation of lesions was higher on MAG and PSIR images compared to VIBE in all size groups with an overall statistically significant difference for VIBE vs. MAG vs. PSIR (p < .001) in the variance analysis. Mean LLC was 0.35±0.01 for VIBE sequences, and 0.73±0.01 for MAG. Conclusion Contrast-optimised PSIR seems to improve imaging characteristics of hepatic metastases in gadoxetate disodium-enhanced scans compared to T1 gradient-echo VIBE sequences.
UR - http://www.scopus.com/inward/record.url?scp=85062600416&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0213408
DO - 10.1371/journal.pone.0213408
M3 - Article
C2 - 30840710
AN - SCOPUS:85062600416
SN - 1932-6203
VL - 14
JO - PLoS ONE
JF - PLoS ONE
IS - 3
M1 - e0213408
ER -