Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement

  • the IMPPACT TAVR Investigators
  • Universität zu Köln
  • Leipzig Heart Institute
  • Kerckhoff Clinic Bad Nauheim
  • Justus-Liebig-Universität Gießen
  • Partner Site Munich Heart Alliance
  • Rabin Medical Center Israel
  • pro3dure medical GmbH
  • University of Bonn and University Hospital Bonn
  • St. Johannes Hospital
  • Universitätsklinikum Hamburg-Eppendorf
  • Medical Faculty and University Hospital Düsseldorf
  • Segeberger Kliniken
  • Università di Enna KORE
  • Tel Aviv Sourasky Medical Center
  • Marienkrankenhaus Hamburg
  • Asklepios-Klinik St. Georg
  • Erasmus University Medical Center
  • Cantonal Hospital of Lucerne
  • Technical University of Munich
  • Hospital Clínico San Carlos
  • Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV)
  • Valladolid University Hospital
  • Albert-Ludwigs-Universität Freiburg
  • Complejo Hospitalario Universitario
  • University Medical Centre Ljubljana
  • ASST Spedali Civili di Brescia
  • Rigshospitalet
  • University of Padova
  • Merlin Park Regional Hospital
  • Hospital de La Santa Creu I Sant Pau
  • University Hospital of the Ruhr-University Bochum
  • Università di Catania
  • Universitätsklinikum Schleswig-Holstein Campus Lübeck
  • Karolinska Institutet

Research output: Contribution to journal › Article › peer-review

17 Scopus citations

Abstract

Background: Prosthesis-patient mismatch after transcatheter aortic valve replacement (TAVR) can be measured echocardiographically (measured prosthesis-patient mismatch [PPMm]) or predicted (predicted prosthesis-patient mismatch [PPMp]) using published effective orifice area (EOA) reference values. However, the clinical implications of PPM post-TAVR remain unclear. Objectives: This study aimed to elucidate the prevalence of PPMm and PPMp post-TAVR and their impact on mortality in a large international cohort. Methods: The IMPPACT TAVR (Impact of Measured or Predicted Prosthesis-pAtient mismatCh after TAVR) registry included 38,808 TAVR patients from 26 international centers. Valve Academic Research Consortium 3 criteria were used to define prosthesis-patient mismatch severity. EOA was determined echocardiographically (PPMm) or predicted (PPMp) based on core lab–derived EOA reference values. The primary endpoint was 2-year all-cause mortality. Results: The prevalence of PPMp (moderate: 6.8%, severe: 0.6%) was significantly lower than that of PPMm (moderate: 20.7%, severe: 4.3%; P < 0.001) with negligible correlation between the 2 methods (Kendall's tau c correlation coefficient: 0.063; P < 0.001). In unadjusted analyses, severe PPMm adversely influenced 2-year survival (HR: 1.22; 95% CI: 1.02-1.45; P = 0.027), whereas severe PPMp was not associated with outcomes (HR: 0.81; 95% CI: 0.55-1.19; P = 0.291). After adjusting for confounders, neither PPMm nor PPMp had a significant effect on 2-year all-cause mortality. Conclusions: PPMm and PPMp were associated with different patient characteristics, with PPMm tending toward worse (especially low flow) and PPMp toward better (especially women) survival. After adjusting for confounders, neither PPMm nor PPMp significantly affected 2-year all-cause mortality. Hence, valve selection should not solely be based on hemodynamics but rather on a holistic approach, including patient and procedural specifics.

Original languageEnglish
Pages (from-to)2626-2635
Number of pages10
JournalJACC: Cardiovascular Interventions
Volume17
Issue number22
DOIs
StatePublished - 25 Nov 2024

Keywords

  • effective orifice area
  • predictors of mortality
  • prevalence
  • prosthesis-patient mismatch
  • transcatheter aortic valve replacement

Fingerprint

Dive into the research topics of 'Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement'. Together they form a unique fingerprint.

Cite this