TY - JOUR
T1 - High throughput determination of BTEX by a one-step fluorescence polarization immunoassay
AU - Eremin, Sergei A.
AU - Knopp, Dietmar
AU - Niessner, Reinhard
AU - Hong, Ji Youn
AU - Park, Song Ja
AU - Chop, Myung Ja
PY - 2005
Y1 - 2005
N2 - For the rapid screening of BTEX (benzene, toluene, ethylbenzene, xylenes), a fluorescence polarization immunoassay (FPIA) was developed using the fluorescence polarization analyzer Abbott TDx. Several fluorescence-labelled tracers were synthesized by binding ethylenediamine fluorescein thiocarbamyl (EDF) to various substituted phenylcarboxylic acids. The binding of 27 tracers with two antisera that can be considered as class-specific for BTEX was investigated to select optimal tracer-antibody pairs. Significant differences were found in binding, titer, sensitivity, and assay kinetics. A best pair of anti-BTEX antiserum and EDF-labelled p-tolylacetic acid tracer was selected for FPIA. To simplify the method, an immunocomplex single reagent was prepared to detect BTEX by a one-step FPIA. One-step FPIA is a rapid homogeneous type of immunoassay that has only one pipetting step, does not need separation of free and bound analyte and can be performed at room temperature. The within-run coefficient of variation was ranged between 3.4% and 5.7%. Furthermore, if the measurement can be done at constant temperature, standards for every assay run are unnecessary. Cross-reactivity studies of petroleum compounds and a BTEX mixture indicated that p-xylene was most reactive with a limit of detection (LOD) of 0.22 μgmL-1 in 50 μL of sample. The LOD for toluene and benzene was 2.1 and 11 μg mL-1 respectively. The immunocomplex single reagent has proven to be significantly more stable than the corresponding solutions of antibody and tracer.
AB - For the rapid screening of BTEX (benzene, toluene, ethylbenzene, xylenes), a fluorescence polarization immunoassay (FPIA) was developed using the fluorescence polarization analyzer Abbott TDx. Several fluorescence-labelled tracers were synthesized by binding ethylenediamine fluorescein thiocarbamyl (EDF) to various substituted phenylcarboxylic acids. The binding of 27 tracers with two antisera that can be considered as class-specific for BTEX was investigated to select optimal tracer-antibody pairs. Significant differences were found in binding, titer, sensitivity, and assay kinetics. A best pair of anti-BTEX antiserum and EDF-labelled p-tolylacetic acid tracer was selected for FPIA. To simplify the method, an immunocomplex single reagent was prepared to detect BTEX by a one-step FPIA. One-step FPIA is a rapid homogeneous type of immunoassay that has only one pipetting step, does not need separation of free and bound analyte and can be performed at room temperature. The within-run coefficient of variation was ranged between 3.4% and 5.7%. Furthermore, if the measurement can be done at constant temperature, standards for every assay run are unnecessary. Cross-reactivity studies of petroleum compounds and a BTEX mixture indicated that p-xylene was most reactive with a limit of detection (LOD) of 0.22 μgmL-1 in 50 μL of sample. The LOD for toluene and benzene was 2.1 and 11 μg mL-1 respectively. The immunocomplex single reagent has proven to be significantly more stable than the corresponding solutions of antibody and tracer.
KW - BTEX
KW - Immunoassay
KW - Immunodetection
UR - http://www.scopus.com/inward/record.url?scp=27744501464&partnerID=8YFLogxK
U2 - 10.1071/EN04082
DO - 10.1071/EN04082
M3 - Article
AN - SCOPUS:27744501464
SN - 1448-2517
VL - 2
SP - 227
EP - 234
JO - Environmental Chemistry
JF - Environmental Chemistry
IS - 3
ER -