TY - JOUR
T1 - High Quality Performance of Novel Immunoassays for the Sensitive Quantification of Soluble PD-1, PD-L1 and PD-L2 in Blood
AU - Krueger, Kimberly
AU - Mayer, Zsuzsanna
AU - Gerckens, Miriam
AU - Boeck, Stefan
AU - Luppa, Peter
AU - Holdenrieder, Stefan
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/10
Y1 - 2022/10
N2 - Programmed death-1 receptor PD-1(CD279) and its corresponding ligands PD-L1(CD274, B7-H1) and PD-L2(CD273, B7-DC) play important roles in physiological immune tolerance and for immune escape in cancer disease. Hence, the establishment and analytical validation of a novel enzyme-linked immunosorbent assay (ELISA) to measure soluble PD-1, PD-L1 and PD-L2 in blood samples according to high quality standards is required. Antibody pairs were used to establish novel highly sensitive ELISAs for all three markers on an open electrochemiluminescence Quickplex platform. Analytical validation comprised intra- and interassay imprecision, limit of quantification, dilution linearity, material comparison and analytical selectivity testing. The methods demonstrated a broad dynamic range and precise measurements down to the pg/mL range. The coefficient of variation (CV) during the intra-assay imprecision measurements with three patient pools did not exceed 10% for all three assays (PD-1: 6.4%, 6.5%, 7.8%, PD-L1: 7.1%, 4.2%, 6.8%; PD-L2: 4.5%, 10.0%, 9.9%). Dilution linearity experiments in both buffer and heparin plasma displayed good linearity. Selectivity was shown for each marker in titration cross-reactivity experiments up to concentrations of at least 15 ng/mL of these, possibly confounding other markers. Soluble PD-1, PD-L1 and PD-L2 can be measured highly sensitively in serum and plasma and can safely be applied to clinical study settings.
AB - Programmed death-1 receptor PD-1(CD279) and its corresponding ligands PD-L1(CD274, B7-H1) and PD-L2(CD273, B7-DC) play important roles in physiological immune tolerance and for immune escape in cancer disease. Hence, the establishment and analytical validation of a novel enzyme-linked immunosorbent assay (ELISA) to measure soluble PD-1, PD-L1 and PD-L2 in blood samples according to high quality standards is required. Antibody pairs were used to establish novel highly sensitive ELISAs for all three markers on an open electrochemiluminescence Quickplex platform. Analytical validation comprised intra- and interassay imprecision, limit of quantification, dilution linearity, material comparison and analytical selectivity testing. The methods demonstrated a broad dynamic range and precise measurements down to the pg/mL range. The coefficient of variation (CV) during the intra-assay imprecision measurements with three patient pools did not exceed 10% for all three assays (PD-1: 6.4%, 6.5%, 7.8%, PD-L1: 7.1%, 4.2%, 6.8%; PD-L2: 4.5%, 10.0%, 9.9%). Dilution linearity experiments in both buffer and heparin plasma displayed good linearity. Selectivity was shown for each marker in titration cross-reactivity experiments up to concentrations of at least 15 ng/mL of these, possibly confounding other markers. Soluble PD-1, PD-L1 and PD-L2 can be measured highly sensitively in serum and plasma and can safely be applied to clinical study settings.
KW - ELISA
KW - PD-1
KW - PD-L1
KW - PD-L2
KW - analytical validation
UR - http://www.scopus.com/inward/record.url?scp=85140656182&partnerID=8YFLogxK
U2 - 10.3390/biomedicines10102405
DO - 10.3390/biomedicines10102405
M3 - Article
AN - SCOPUS:85140656182
SN - 2227-9059
VL - 10
JO - Biomedicines
JF - Biomedicines
IS - 10
M1 - 2405
ER -