Ground Temperatures at the Heat Withdrawal by Means of Heat Pump.

Translated title of the contribution: Ground Temperatures at the Heat Withdrawal by Means of Heat Pump.

Research output: Contribution to journalArticlepeer-review

Abstract

The author reports on the measurements at a ground heat pump which serves for the heat supply of a self-contained house. The quantities were measured over three heating periods, such as the heat withdrawal from the ground, the electric current consumption of the heat pump, the outside air temperature, and the temperature profiles within the ground.

Translated title of the contributionGround Temperatures at the Heat Withdrawal by Means of Heat Pump.
Original languageEnglish
Pages (from-to)393-396
Number of pages4
JournalHLH Heizung Luftung/Klima Haustechnik
Volume26
Issue number11
StatePublished - 1975