TY - GEN
T1 - Global registration of ultrasound to MRI using the LC2 metric for enabling neurosurgical guidance
AU - Wein, Wolfgang
AU - Ladikos, Alexander
AU - Fuerst, Bernhard
AU - Shah, Amit
AU - Sharma, Kanishka
AU - Navab, Nassir
PY - 2013
Y1 - 2013
N2 - Automatic and robust registration of pre-operative magnetic resonance imaging (MRI) and intra-operative ultrasound (US) is essential to neurosurgery. We reformulate and extend an approach which uses a Linear Correlation of Linear Combination (LC2)-based similarity metric, yielding a novel algorithm which allows for fully automatic US-MRI registration in the matter of seconds. It is invariant with respect to the unknown and locally varying relationship between US image intensities and both MRI intensity and its gradient. The overall method based on this both recovers global rigid alignment, as well as the parameters of a free-form-deformation (FFD) model. The algorithm is evaluated on 14 clinical neurosurgical cases with tumors, with an average landmark-based error of 2.52mm for the rigid transformation. In addition, we systematically study the accuracy, precision, and capture range of the algorithm, as well as its sensitivity to different choices of parameters.
AB - Automatic and robust registration of pre-operative magnetic resonance imaging (MRI) and intra-operative ultrasound (US) is essential to neurosurgery. We reformulate and extend an approach which uses a Linear Correlation of Linear Combination (LC2)-based similarity metric, yielding a novel algorithm which allows for fully automatic US-MRI registration in the matter of seconds. It is invariant with respect to the unknown and locally varying relationship between US image intensities and both MRI intensity and its gradient. The overall method based on this both recovers global rigid alignment, as well as the parameters of a free-form-deformation (FFD) model. The algorithm is evaluated on 14 clinical neurosurgical cases with tumors, with an average landmark-based error of 2.52mm for the rigid transformation. In addition, we systematically study the accuracy, precision, and capture range of the algorithm, as well as its sensitivity to different choices of parameters.
UR - http://www.scopus.com/inward/record.url?scp=84885751488&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-40811-3_5
DO - 10.1007/978-3-642-40811-3_5
M3 - Conference contribution
C2 - 24505646
AN - SCOPUS:84885751488
SN - 9783642408106
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 34
EP - 41
BT - Medical Image Computing and Computer-Assisted Intervention, MICCAI 2013 - 16th International Conference, Proceedings
T2 - 16th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2013
Y2 - 22 September 2013 through 26 September 2013
ER -