Geometry calibration for X-ray equipment in radiation treatment devices and estimation of remaining patient alignment errors

Boris P. Selby, Georgios Sakas, Stefan Walter, Uwe Stilla

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

6 Scopus citations

Abstract

Positioning a patient accurately in treatment devices is crucial for radiological treatment, especially if accuracy vantages of particle beam treatment are exploited. To avoid sub-millimeter misalignments, X-ray images acquired from within the device are compared to a CT to compute respective alignment corrections. Unfortunately, deviations of the underlying geometry model for the imaging system degrade the achievable accuracy. We propose an automatic calibration routine, which bases on the geometry of a phantom and its automatic detection in digital radiographs acquired for various geometric device settings during the calibration. The results from the registration of the phantom's X-ray projections and its known geometry are used to update the model of the respective beamlines, which is used to compute the patient alignment correction. The geometric calibration of a beamline takes all nine relevant degrees of freedom into account, including detector translations in three directions, detector tilt by three axes and three possible translations for the X-ray tube. Introducing a stochastic model for the calibration we are able to predict the patient alignment deviations resulting from inaccuracies inherent to the phantom design and the calibration. Comparisons of the alignment results for a treatment device without calibrated imaging systems and a calibrated device show that an accurate calibration can enhance alignment accuracy.

Original languageEnglish
Title of host publicationMedical Imaging 2008 - Physics of Medical Imaging
DOIs
StatePublished - 2008
EventMedical Imaging 2008 - Physics of Medical Imaging - San Diego, CA, United States
Duration: 18 Feb 200821 Feb 2008

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6913
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2008 - Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period18/02/0821/02/08

Keywords

  • Alignment correction
  • Calibration
  • Digital X-ray
  • Error estimation
  • Image registration
  • Image-guided radiotherapy
  • Stereo geometry
  • Template matching

Fingerprint

Dive into the research topics of 'Geometry calibration for X-ray equipment in radiation treatment devices and estimation of remaining patient alignment errors'. Together they form a unique fingerprint.

Cite this