TY - JOUR
T1 - Five-year clinical outcomes in patients with diabetes mellitus treated with polymer-free sirolimus- and probucol-eluting stents versus second-generation zotarolimus-eluting stents
T2 - A subgroup analysis of a randomized controlled trial
AU - for the Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol- and Zotarolimus- Eluting Stents (ISAR-TEST 5) Investigators
AU - Harada, Yukinori
AU - Colleran, Roisin
AU - Kufner, Sebastian
AU - Giacoppo, Daniele
AU - Rheude, Tobias
AU - Michel, Jonathan
AU - Cassese, Salvatore
AU - Ibrahim, Tareq
AU - Laugwitz, Karl Ludwig
AU - Kastrati, Adnan
AU - Byrne, Robert A.
N1 - Publisher Copyright:
© 2016 The Author(s).
PY - 2016/9/1
Y1 - 2016/9/1
N2 - Background: Improved outcomes in patients with diabetes mellitus undergoing percutaneous coronary intervention remain an unmet clinical need. We assessed the long-term efficacy and safety of novel polymer-free sirolimus- and probucol-eluting stent in diabetic patients enrolled in intracoronary stenting and angiographic results: test efficacy of sirolimus- and probucol-eluting versus zotarolimus-eluting stents 5 trial. Methods: In a pre-specified subgroup analysis, outcomes of diabetic patients treated with a sirolimus- and probucol-eluting stent or a second-generation zotarolimus-eluting stent were compared. The primary endpoint was a device-oriented composite outcome comprising cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR) at 5-year follow-up. Event-free survival was assessed using the Kaplan-Meier method. Hazard ratios (HR) and 95 % confidence intervals (CI) were estimated from univariate Cox proportional hazards models. Results: A total of 870 patients with diabetes mellitus were treated with either a sirolimus- and probucol-eluting stent (n = 575) or a second-generation zotarolimus-eluting stent (n = 295). At 5 years, the rate of device-oriented composite endpoint was comparable between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent (32.9 versus 33.4 %, HR 0.88, 95 % CI 0.76-1.26). No significant differences were observed between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent groups in the incidence of cardiac death (15.6 versus 16.7 % HR 0.92, 95 % CI 0.63-1.32), target-vessel MI (4.6 versus 6.6 %, HR 0.73, 95 % CI 0.40-1.34), and TLR (18.6 versus 18.8 %, HR 1.00, 95 % CI, 0.72-1.41). The rate of definite or probable stent thrombosis was low and similar in both groups (2.5 versus 2.6 %, HR 1.02, 95 % CI, 0.41-2.52). Conclusions: In patients with diabetes the long-term efficacy and safety of a polymer-free sirolimus- and probucol-eluting stent were comparable to a second-generation durable polymer zotarolimus-eluting stent. Trial registration ClinicalTrials.gov NCT00598533.
AB - Background: Improved outcomes in patients with diabetes mellitus undergoing percutaneous coronary intervention remain an unmet clinical need. We assessed the long-term efficacy and safety of novel polymer-free sirolimus- and probucol-eluting stent in diabetic patients enrolled in intracoronary stenting and angiographic results: test efficacy of sirolimus- and probucol-eluting versus zotarolimus-eluting stents 5 trial. Methods: In a pre-specified subgroup analysis, outcomes of diabetic patients treated with a sirolimus- and probucol-eluting stent or a second-generation zotarolimus-eluting stent were compared. The primary endpoint was a device-oriented composite outcome comprising cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR) at 5-year follow-up. Event-free survival was assessed using the Kaplan-Meier method. Hazard ratios (HR) and 95 % confidence intervals (CI) were estimated from univariate Cox proportional hazards models. Results: A total of 870 patients with diabetes mellitus were treated with either a sirolimus- and probucol-eluting stent (n = 575) or a second-generation zotarolimus-eluting stent (n = 295). At 5 years, the rate of device-oriented composite endpoint was comparable between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent (32.9 versus 33.4 %, HR 0.88, 95 % CI 0.76-1.26). No significant differences were observed between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent groups in the incidence of cardiac death (15.6 versus 16.7 % HR 0.92, 95 % CI 0.63-1.32), target-vessel MI (4.6 versus 6.6 %, HR 0.73, 95 % CI 0.40-1.34), and TLR (18.6 versus 18.8 %, HR 1.00, 95 % CI, 0.72-1.41). The rate of definite or probable stent thrombosis was low and similar in both groups (2.5 versus 2.6 %, HR 1.02, 95 % CI, 0.41-2.52). Conclusions: In patients with diabetes the long-term efficacy and safety of a polymer-free sirolimus- and probucol-eluting stent were comparable to a second-generation durable polymer zotarolimus-eluting stent. Trial registration ClinicalTrials.gov NCT00598533.
KW - Diabetes
KW - Drug-Eluting Stent
KW - Probucol
KW - Sirolimus
KW - Zotarolimus
UR - http://www.scopus.com/inward/record.url?scp=84984839639&partnerID=8YFLogxK
U2 - 10.1186/s12933-016-0429-y
DO - 10.1186/s12933-016-0429-y
M3 - Article
C2 - 27586678
AN - SCOPUS:84984839639
SN - 1475-2840
VL - 15
JO - Cardiovascular Diabetology
JF - Cardiovascular Diabetology
IS - 1
M1 - 124
ER -