TY - GEN
T1 - First 3D printed medical robot for ENT surgery - Application specific manufacturing of laser sintered disposable manipulators
AU - Entsfellner, Konrad
AU - Kuru, Ismail
AU - Maier, Thomas
AU - Gumprecht, Jan D.J.
AU - Lueth, Tim C.
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/10/31
Y1 - 2014/10/31
N2 - The Stapedotomy is a standard ENT (ear, nose and throat) surgery, where the surgeons use surgical micro hooks and forceps to replace the stapes with a small titanium implant. However, there are some challenges with this procedure. Especially, the non-ergonomic posture of the surgeon increases the hand tremor and leads to an inaccurate positioning of the implant. This may cause hearing loss and the patient may need a revision operation. In this paper, we present the first laser sintered disposable manipulator for ENT surgery, which allows the surgeon to move a micro hook in three directions via a joystick console, while his/her hands are located on an armrest. This may increase the surgical outcome by enhancing the ergonomics and therefore may reduce the number of revision operations. We show that the fabrication cost of the single-use robot does not increase the operation expenses drastically. To conclude, our preliminary evaluation with a middle ear phantom indicates that a basic surgical maneuver can be performed via the presented robotic system.
AB - The Stapedotomy is a standard ENT (ear, nose and throat) surgery, where the surgeons use surgical micro hooks and forceps to replace the stapes with a small titanium implant. However, there are some challenges with this procedure. Especially, the non-ergonomic posture of the surgeon increases the hand tremor and leads to an inaccurate positioning of the implant. This may cause hearing loss and the patient may need a revision operation. In this paper, we present the first laser sintered disposable manipulator for ENT surgery, which allows the surgeon to move a micro hook in three directions via a joystick console, while his/her hands are located on an armrest. This may increase the surgical outcome by enhancing the ergonomics and therefore may reduce the number of revision operations. We show that the fabrication cost of the single-use robot does not increase the operation expenses drastically. To conclude, our preliminary evaluation with a middle ear phantom indicates that a basic surgical maneuver can be performed via the presented robotic system.
UR - https://www.scopus.com/pages/publications/84911498898
U2 - 10.1109/IROS.2014.6943166
DO - 10.1109/IROS.2014.6943166
M3 - Conference contribution
AN - SCOPUS:84911498898
T3 - IEEE International Conference on Intelligent Robots and Systems
SP - 4278
EP - 4283
BT - IROS 2014 Conference Digest - IEEE/RSJ International Conference on Intelligent Robots and Systems
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2014
Y2 - 14 September 2014 through 18 September 2014
ER -